HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0a release notes (5697-0359 - Page 27

On the DC SAN Director Multi-protocol Extension Blade, GigE ports 0-9 or 10-GbE port 1

Page 27 highlights

• Software compression (available on the 1606 Extension SAN Switch) modes 2 and 3 are not supported in FICON environments; they are supported only in Open Systems environments. • Software compression (modes 2 and 3) generally gives a better compression ratio, but not the throughput or bandwidth across all six GE ports. HP recommends software compression for lowthroughput links and supports throughput up to 2 Gb/s across all 6 GE ports. • To perform the following operations you must delete the FCIP configuration on the affected ports first: • Switching modes between 1G/10G/Dual • Moving VE/GE port between logical switches • The DC SAN Director Multi-protocol Extension Blade supports three operating modes: • Mode 1: 10 1-GbE ports mode (default) • Mode 2: 10 1-GbE ports and 1 10-GbE port • Mode 3: 2 10-GbE ports Modes 2 and 3 require the slot-based 10-GbE FCIP license. • ARL is not supported on 10-Gb tunnels. • IPv6, IPsec, DiffServ VLAN tagging, and In-band Management are not supported on the 1606 Extension SAN Switch or DC SAN Director Multi-protocol Extension Blade. • Fabric OS 6.3 supports only up to four 1-Gb circuits per VE/FCIP tunnel for the 1-Gb interfaces. A VE/FCIP tunnel created over 10-Gb interfaces will be limited to 10 circuits created using IPIFs on the same 10-GbE port (and no more than 1 Gb per circuit). • As a recommended best practice, the VE tunnel should not be oversubscribed (for example, 8-Gb FC traffic over 500 Mb/s tunnel). General guidelines are 2:1 subscription without compression and 4:1 with compression. • Nondisruptive firmware activation on Fabric OS 6.3 will disrupt I/O traffic on FCIP links. • FCR (VEX) is not supported on the DC SAN Director Multi-protocol Extension Blade but is supported on the 1606 Extension SAN Switch. • Differences between the 1606 Extension SAN Switch/DC SAN Director Multi-protocol Extension Blade platforms and previous-generation 7500/FR4-18i platforms include: • On the 1606 Extension SAN Switch, the GigE port does not directly correlate to a VE_Port. • On the DC SAN Director Multi-protocol Extension Blade, GigE ports 0-9 or 10-GbE port 1 (xge1) correspond to VE_Ports 12-21, and 10-GbE port 0 (xge0) corresponds to VE_Ports 2231. • The CLI syntax for the 1606 Extension SAN Switch/DC SAN Director Multi-protocol Extension Blade varies from the 7500/FR4-18i. See the Brocade Fabric OS Command Reference document for Fabric OS 6.3 for details. • Both ends of a tunnel must be identically configured for the Compression, FastWrite, and Tape Pipeline options. If a mismatch exists, the tunnel will not be established and the TCP virtual connections will be removed. • Under traffic isolation (TI) zone configurations with failover enabled, non-TI zone traffic will use the dedicated path if no other E or VE paths through the fabric exist, or if the nondedicated paths are not the shortest paths. (A higher bandwidth tunnel with multiple circuits will become the shortest path compared to a single tunnel.) • A VE/VEX tunnel and E/EX FC port cannot connect to the same domain at the same time. • The recommended Keep Alive Timeout must be the same on the tunnel and circuits on the switches on both sides of a link. • The 1606 Extension SAN Switch and DC SAN Director Multi-protocol Extension Blade cannot receive a ping from an external device (for example, a Windows PC). • Latency measurements supported on FCIP tunnels (tested limit under Fabric OS 6.3.0): HP StorageWorks Fabric OS 6.3.0a release notes 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Software compression (available on the 1606 Extension SAN Switch) modes 2 and 3 are not
supported in FICON environments; they are supported only in Open Systems environments.
Software compression (modes 2 and 3) generally gives a better compression ratio, but not the
throughput or bandwidth across all six GE ports. HP recommends software compression for low-
throughput links and supports throughput up to 2 Gb/s across all 6 GE ports.
To perform the following operations you must delete the FCIP configuration on the affected ports
first:
Switching modes between 1G/10G/Dual
Moving VE/GE port between logical switches
The DC SAN Director Multi-protocol Extension Blade supports three operating modes:
Mode 1: 10 1-GbE ports mode (default)
Mode 2: 10 1-GbE ports and 1 10-GbE port
Mode 3: 2 10-GbE ports
Modes 2 and 3 require the slot-based 10-GbE FCIP license.
ARL is not supported on 10-Gb tunnels.
IPv6, IPsec, DiffServ VLAN tagging, and In-band Management are not supported on the 1606
Extension SAN Switch or DC SAN Director Multi-protocol Extension Blade.
Fabric OS 6.3 supports only up to four 1-Gb circuits per VE/FCIP tunnel for the 1-Gb interfaces.
A VE/FCIP tunnel created over 10-Gb interfaces will be limited to 10 circuits created using IPIFs
on the same 10-GbE port (and no more than 1 Gb per circuit).
As a recommended best practice, the VE tunnel should not be oversubscribed (for example, 8-Gb
FC traffic over 500 Mb/s tunnel). General guidelines are 2:1 subscription without compression
and 4:1 with compression.
Nondisruptive firmware activation on Fabric OS 6.3 will disrupt I/O traffic on FCIP links.
FCR (VEX) is not supported on the DC SAN Director Multi-protocol Extension Blade but is supported
on the 1606 Extension SAN Switch.
Differences between the 1606 Extension SAN Switch/DC SAN Director Multi-protocol Extension
Blade platforms and previous-generation 7500/FR4-18i platforms include:
On the 1606 Extension SAN Switch, the GigE port does not directly correlate to a VE_Port.
On the DC SAN Director Multi-protocol Extension Blade, GigE ports 0-9 or 10-GbE port 1
(xge1) correspond to VE_Ports 12-21, and 10-GbE port 0 (xge0) corresponds to VE_Ports 22-
31.
The CLI syntax for the 1606 Extension SAN Switch/DC SAN Director Multi-protocol Extension
Blade varies from the 7500/FR4-18i. See the
Brocade Fabric OS Command Reference document
for Fabric OS 6.3 for details.
Both ends of a tunnel must be identically configured for the Compression, FastWrite, and Tape
Pipeline options. If a mismatch exists, the tunnel will not be established and the TCP virtual connec-
tions will be removed.
Under traffic isolation (TI) zone configurations with failover enabled, non-TI zone traffic will use
the dedicated path if no other E or VE paths through the fabric exist, or if the nondedicated paths
are not the shortest paths. (A higher bandwidth tunnel with multiple circuits will become the shortest
path compared to a single tunnel.)
A VE/VEX tunnel and E/EX FC port cannot connect to the same domain at the same time.
The recommended Keep Alive Timeout must be the same on the tunnel and circuits on the switches
on both sides of a link.
The 1606 Extension SAN Switch and DC SAN Director Multi-protocol Extension Blade cannot
receive a ping from an external device (for example, a Windows PC).
Latency measurements supported on FCIP tunnels (tested limit under Fabric OS 6.3.0):
HP StorageWorks Fabric OS 6.3.0a release notes