HP StorageWorks 2/140 FW 05.02.00 and SW 07.01.00 and 07.02.00 HP StorageWorks - Page 19
Known Issues, Embedded Web Server access to modify zones is limited to first 255 zones, Workaround
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Known Issues Known Issues This section describes the known issues related to the Director 2/64 and Director 2/140. Embedded Web Server access to modify zones is limited to first 255 zones If you have an active zone set of greater than 255 zones, you will not be able to access the zones past the 255th zone using the Embedded Web Server (EWS). The higher number zone names are listed, but when accessed to modify the zone (for example, the zone that would be numbered "n"), you will get the zone member list for the (n-255) zone. This will be corrected in a future firmware release. Workaround Using HAFM to manage directors and edge switches will allow you to modify zones in zone sets with greater than 255 zones. SNMP trap reports incorrect FRU position When an SNMP trap is sent and reports a FRU position number, the reported number is one greater than the actual FRU position that caused the SNMP trap to be issued. Workaround None. Director Release Notes 19