HP StorageWorks 2/16N Brocade Access Gateway Administrator's Guide - Supportin - Page 55
AG-1007, AG-1008, AG-1009
View all HP StorageWorks 2/16N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
AG-1007 D Severity Check GBIC and other connecting cables and re-enable the F_Port using the portEnable command. WARNING AG-1007 Message , [AG-1007], ,, WARNING, , FLOGI response not received for the N_Port connected to fabric Probable Cause Recommended Action Severity Indicates the N_Port which is connected to the fabric switch is not online. The N_Port has been disabled. Check the connectivity between Access Gateway N_Port and fabric switch port. WARNING AG-1008 Message , [AG-1008], ,, WARNING, , Invalid PLOGI response from the fabric on the N_Port Probable Cause Recommended Action Severity Indicates that the fabric switch management server did not accept the login (PLOGI) request sent by the Access Gateway from the specified N_Port. Verify the configuration on the fabric switch that is connected to the Access Gateway. If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1009 Message , [AG-1009], ,, WARNING, , FLOGI sent from N-Port failed Probable Cause Recommended Action Indicates that the fabric login (FLOGI) request sent to the fabric switch from the Access Gateway failed. Verify the configuration of the fabric switch.. Access Gateway Administrator's Guide D-7 Publication Number: 53-1000430-01