HP StorageWorks 2/16N Brocade Access Gateway Administrator's Guide - Supportin - Page 56
AG-1010, AG-1011, AG-1012
View all HP StorageWorks 2/16N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
D AG-1010 Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1010 Message , [AG-1010], ,, WARNING, , PLOGI sent from N-Port failed Probable Cause Recommended Action Severity Indicates an internal problem with the Secure Fabric OS. Verify the configuration of the fabric switch.. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1011 Message , [AG-1011], ,, WARNING, , FDISC sent from N-Port failed Probable Cause Recommended Action Severity Indicates that the discover F_Port service parameters (FDISC) request sent to the fabric switch from the Access Gateway failed. Verify the configuration of the fabric switch.. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1012 Message , [AG-1012], ,, WARNING, , FDISC sent from N-Port failed Probable Indicates that the N_Port logout request sent to the fabric switch from the Access Gateway failed. Cause D-8 Access Gateway Administrator's Guide Publication Number: 53-1000430-01