HP StorageWorks 2000fc HP StorageWorks 2312fc and 2324fc Modular Smart Array u - Page 32
Hard drive LEDs, Description, Online/Activity green, Fault/UID amber/blue
View all HP StorageWorks 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Hard drive LEDs 12 21 LED Description 1 Fault/UID (amber/blue) 2 Online/Activity (green) Table 5 Hard drive LED combinations Online/Activity (green) On Fault/UID (amber/blue) Off Blinking irregularly Off Off Amber; blinking regularly (1 Hz) On Blinking irregularly Off Off On or blinking Amber; blinking regularly (1 Hz) Amber; blinking regularly (1 Hz) Amber; solid Blue; solid Blue; solid Description Normal operation. The drive is online, but it is not currently active. The drive is active and operating normally. Offline; the drive is not being accessed. A predictive failure alert may have been received for this device. Further investigation is required. Online; no activity. A predictive failure alert may have been received for this device. Further investigation is required. The drive is active, but a predictive failure alert may have been received for this drive. Further investigation is required. Offline; no activity. A critical fault condition has been identified for this drive. Offline. The drive has been selected by a management application (SMU). The controller is driving I/O to the drive, and it has been selected by a management application (SMU). 32 LED descriptions