Power supply LEDs Power redundancy is achieved through two independent load-sharing power supplies. In the event of a power supply failure, or the failure of the power source, the storage system can operate continuously on a single power supply. Greater redundancy can be achieved by connecting the power supplies to separate circuits. 1 1 2 2 AC model LED Description 1 Input Source Power good 2 DC Voltage/Fan Fault/Service Required DC model Definition Green - Power is on and input voltage is normal. Off - Power is off or input voltage is below the minimum threshold. Amber - DC output voltage is out of range or a fan is operating below the minimum required RPM. Off- DC output voltage is normal. HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 37