HP StorageWorks 2500 HP StorageWorks 2500 Disk System User Guide (5697-5922, N - Page 34
Setting the enclosure ID En, FC-AL loops
View all HP StorageWorks 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
4. Attach one end of an FC cable to the SFP in port 1 on I/O module A and the other end of the cable to either: • The SFP in port 2 on I/O module A on the next enclosure, if one exists, or • The HBA if you are installing the last DS2500 in the loop 5. Coil the excess cable and secure the coiled cable behind the rail with cable ties. CAUTION: Avoid coiling the FC cable tighter then the acceptable bend radius of 1.375 inches. 6. Connect the FC cables on the B loop by repeating Step 3 through Step 5. 7. Verify the FC connections by observing that the port status indicators are on and steady. 8. Verify that the EMU heartbeat indicator is flashing. 9. Verify that the disk drives are online by observing their online LEDs. 1 3 10 2 1. Loop B-Connects to HBA 2. Loop B-Connects to HBA Figure 23 FC-AL loops 4 25176a 3. Loop A-Connects to HBA 4. Loop A-Connects to HBA Setting the enclosure ID (En) You must assign a unique enclosure ID and corresponding loop ID to each DS2500 in a loop. See Table 3 for acceptable enclosure IDs and the corresponding loop IDs. NOTE: All enclosures must have a hard address in order to function properly with HP-UX software. 34 Installation