HP StorageWorks 2500 HP StorageWorks 2500 Disk System User Guide (5697-5922, N - Page 81
EMU error conditions, Table 25 Temperature threshold error conditions
View all HP StorageWorks 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Table 25 Temperature threshold error conditions Error Severity condition Description Actions 0.4.en.01 Noncritical 0.4.en.02 Critical The component in location en is approaching the high temperature critical threshold. 1. Ensure that all components are properly installed to maintain proper air flow. The component in location en has reached a temperature above the high temperature critical threshold. CAUTION: 2. Ensure that nothing is obstructing the air flow at either the front of the enclosure or the rear of the blowers. Continued operation under these 3. Ensure that both blowers conditions may result in component are operating properly (the failure. indicators are on). Replace blower if necessary. 4. Verify that the ambient temperature is in the range of 10°C to 35°C (50°F to 95°F). 5. Contact your HP-authorized service representative. 0.4.en.03 Noncritical 0.4.en.04 Critical The component in location en is approaching the low temperature-critical threshold. 1. Verify that the ambient temperature is in the range of 10°C to 35°C (50°F to 95°F). The component in location en has reached a temperature below the low 2. Contact your HP-authorized service representative. temperature-critical threshold. 0.4.en.05 Unrecoverable The EMU has determined that the average temperature of two of the three component areas (EMU, disk drives, and power supplies) exceeds the critical level. Enclosure shutdown is imminent. An automatic shutdown and possible data corruption may result if the procedure below is not performed immediately. 1. Ensure that all components are properly installed to maintain proper air flow. 2. Ensure that nothing is obstructing the air flow at either the front of the enclosure or the rear of the blowers. 3. Ensure that both blowers are operating properly (the indicators are on). Replace blower if necessary. 4. Verify that the ambient temperature is in the range of 10°C to 35°C (50°F to 95°F). 5. Contact your HP-authorized service representative. EMU error conditions The format of an EMU error condition report is 0.7.01.ec, where: • 0.7. identifies an EMU error. • 01. Because there is only one EMU in a DS2500, the element number is always 01. • ec is the error code. 2500 Disk System user guide 81