HP StorageWorks 4/64 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 159
Recommended action, Status, Color, Table 30 Director and application blade LED descriptions
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
Table 30 Director and application blade LED descriptions LED purpose Color Power LED Steady green No light (LED is off) Status Blade has been enabled. Blade has not been enabled. Recommended action No action required Ensure blade is firmly seated. Status No light (LED is off) LED Blade is either healthy or does not Verify that the power LED is on. have power. Steady amber Blade is faulty. Ensure blade is firmly seated and check status with slotShow command. If LED remains amber, contact HP. Slow-flashing amber (on 2 seconds, then off 2 seconds) Blade is not seated correctly or is Pull blade out and reseat it. If LED faulty. continues to flash, replace blade. Fast-flashing amber (on Environmental range exceeded. 1/2 second, then off 1/2 second) Check for out-of-bounds environmental condition and correct it. Port No light (LED is off) Status Port has no incoming power, or there is no light or signal carrier detected. Verify that the power LED is on, check the transceiver and cable. Polling is in progress. Allow 60 seconds for polling to complete. Connected device is configured Verify the status of the connected in an offline state. device. Steady green Port is online (connected to an No action required external device) but has no traffic. Slow-flashing green (on 1 Port is online but segmented, in- Verify that the correct device is at- second, then off 1 dicating a loopback plug or cable tached to the DC04 SAN Director. second) or an incompatible switch. Fast-flashing green (on 1/4 second, then off 1/4 second Port is in internal loopback (dia- No action required gnostic). Flickering green Port is online, with traffic flowing No action required through port. Steady amber Port is receiving light or signal carrier, but it is not online yet. Reset port from workstation using the portEnable or portCfgPersistentEnable command. Slow-flashing amber (on 2 seconds, then off 2 seconds) Port is disabled due to diagnostic tests or portDisable or portCfgPersistentEnable command. Reset port from workstation using the portEnable or portCfgPersistentEnable command. HP StorageWorks DC and DC04 SAN Backbone Director Switches 159