HP StorageWorks 4/64 HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 203
Reconnecting to the network and the fabric
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 203 highlights
4. Verify that all the IP address information is correct by typing ipaddrshow and checking the results against the IP information recorded in the config-miscinfo.txt file. rsl8-st03-dcx-1:admin> ipaddrshow SWITCH Ethernet IP Address: 10.32.50.12 Ethernet Subnetmask: 255.55.0.0 Fibre Channel IP Address: 1.2.3.4 Fibre Channel Subnetmask: 255.255.255.0 CP0 Ethernet IP Address: 10.32.50.10 Ethernet Subnetmask: 255.55.0.0 HostName : cp0 Gateway Address: 10.32.40.1 CP1 Ethernet IP Address: 10.32.50.11 Ethernet Subnetmask: 255.55.0.0 HostName : cp1 Gateway Address: 10.32.40.1 Backplane IP address of CP0 : 10.0.0.5 Backplane IP address of CP1 : 10.0.0.6 rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin> Reconnecting to the network and the fabric See the cable routing information that was recorded in Table 40 on page 206 for the following steps: 1. Connect the CP blades to the local area network: a. Insert the appropriate Ethernet cables into each Ethernet port. b. Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected. IMPORTANT: The DC04 SAN Director can be accessed by remote connection using any of the available management tools, such as Telnet or Web Tools. Ensure that the DC04 SAN Director is not modified using other connections during the rest of this procedure. HP StorageWorks DC and DC04 SAN Backbone Director Switches 203