Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1006.0006) (Zoning conflict, device_WWN and device_WWN do not share an ACL hard zone, but device_WWN share a soft zone) (A1007.0001) (Security: Unspecified zoning enforcement error) The named zone members cannot communicate because they are members of different hard zones. Place both zone members in the same hard zone or exclude both from hard zones. A device was not authorized or it failed security checks and will not be allowed to join the fabric. None (A1007.0002) (Security: Remote Switch with WorldWide Name (WWN) wwn configured for chap, no chap configured for local switch. 2-way Authentication Failure) The device worldwide name (WWN) is either not configured in the security database, or it is not configured for Challenge Handshake Authentication Protocol (CHAP). Add the device WWN to the active security set if it missing, or modify the group to allow for CHAP authentication with the other devices. (A1007.0005) (Security: Authentication request was rejected by port.) Indicates that a remote switch rejected a security authentication attempt. The port will isolate. Checks the security configuration on the remote switch to determine the problem. (A1007.0006) (Security: Could not validate Authentication Response from port_number, payload seems to be incorrect.) The format of the payload of the response frame does not match what was expected. Check for errors on the remote side of the link. Check the transceiver and cable. Update firmware on remote switch. (A1007.0007) (Security: Fabric Binding (ESA) not supported on remote switch and Fabric Binding is enabled, failing security checks) Either fabric binding is not enabled on the remote switch or the remote switch does not support security at all. Check the security configuration on the remote switch. (A1007.0008) (Security: ESA Response failure, failing security checks) A failure was received during processing of the Exchange Security Attributes (ESA) received frame. Either the payload did not match the standard layout or the payload status indicated a reject. Check for errors on the remote side of the link. Check the transceiver and cable. Update firmware on the remote switch. (A1007.0009) (Security checks EFMD response failure, failing security check.) A remote switch rejected an Exchange Fabric Membership Data (EFMD) frame. The port will be isolated. Check the remote switch for the reason that the EFMD frame was rejected. It is possible that the FabricBindingEnabled parameter is different on the two switches. 8/20q Fibre Channel Switch event messages reference guide 29
![](/manual_guide/products/hewlettpackard-ak241a-hp-storageworks-820q-fibre-channel-switch-event-messages-reference-guide-56977520-2008-67efe39/29.png)