HP StorageWorks 8/20q HP StorageWorks 8/20q Fibre Channel Switch event message - Page 35

Power-on Self Test POST.

Page 35 highlights

Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1007.0039) (Ignoring RADIUS Server server, no shared secret configured) (A1007.003A) (Using local user authentication. No radius servers configured for user authentication) An attempt was made to authenticate a switch login through a Remote Authentication Dial In User Service (RADIUS) server, but no shared secret exists. Configure a shared secret. A Remote Authentication Dial In User Service (RADIUS) configuration was set to authenticate user accounts through a RADIUS server, but no RADIUS server was configured. User accounts will be authenticated by the switch. Correct the user authentication order or configure a RADIUS server. (A3000.0001) (Temp overheat, sensor_name sensor reads value C ALARM SET) The chassis temperature has reached a failure threshold. Check air flow, fan operation, and ambient temperature. If the problem cannot be corrected, power down the switch. (A3001.0001) (Temp overwarm, sensor_name sensor reads value C ALARM SET) The chassis temperature has Check air flow, fan operation, reached a warning threshold. and ambient temperature. (A3002.0001) (sensor name sensor has returned to normal range - ALARM CLEARED) The chassis temperature has returned to the normal range and the alarm condition has been cleared. None (A3003.0001) (IOn) (Hardware error detected. Use 'show switch' for more info.) A fatal hardware error was discovered during the Power-on Self Test (POST) phase of startup. This switch is not currently operational. Enter the show post log command to investigate. (A3003.0002) (POST detected a fatal error the last time it ran and will be re-executed.) A fatal hardware error was discovered from the previous Power-on Self Test (POST). This switch is not currently operational. Enter the show post log command to investigate. (A3004.0001) (Non-fatal hardware error detected. Use 'show post log' for more info) (A3005.0001-000C) (value voltage sensor shows valueV - ALARM SET) (A3006.0001-000C) (value voltage sensor shows valueV - ALARM SET) A non-fatal hardware error was discovered during the Power-on Self Test (POST) phase of startup. A switch voltage sensor is experiencing an out-of-range voltage condition. An out-of-range voltage condition has occurred. Enter the show post log command to investigate. Contact your authorized maintenance provider. Contact your authorized maintenance provider. 8/20q Fibre Channel Switch event messages reference guide 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

8/20q Fibre Channel Switch event messages reference guide
35
(A1007.0039) (Ignoring
RADIUS Server
server
,
no shared secret
configured)
An attempt was made to
authenticate a switch login
through a Remote
Authentication Dial In User
Service (RADIUS) server, but
no shared secret exists.
Configure a shared secret.
(A1007.003A) (Using
local user
authentication. No
radius servers
configured for user
authentication)
A Remote Authentication Dial
In User Service (RADIUS)
configuration was set to
authenticate user accounts
through a RADIUS server, but
no RADIUS server was
configured. User accounts
will be authenticated by the
switch.
Correct the user
authentication order or
configure a RADIUS server.
(A3000.0001) (Temp
overheat,
sensor_name
sensor reads
value
C -
ALARM SET)
The chassis temperature has
reached a failure threshold.
Check air flow, fan operation,
and ambient temperature. If
the problem cannot be
corrected, power down the
switch.
(A3001.0001) (Temp
overwarm,
sensor_name
sensor reads
value
C -
ALARM SET)
The chassis temperature has
reached a warning threshold.
Check air flow, fan operation,
and ambient temperature.
(A3002.0001) (
sensor
name
sensor has
returned to normal
range - ALARM CLEARED)
The chassis temperature has
returned to the normal range
and the alarm condition has
been cleared.
None
(A3003.0001) (IO
n
)
(Hardware error
detected. Use 'show
switch' for more info.)
A fatal hardware error was
discovered during the
Power-on Self Test (POST)
phase of startup. This switch
is not currently operational.
Enter the
show post log
command to investigate.
(A3003.0002) (POST
detected a fatal error
the last time it ran and
will be re-executed.)
A fatal hardware error was
discovered from the previous
Power-on Self Test (POST).
This switch is not currently
operational.
Enter the
show post log
command to investigate.
(A3004.0001) (Non-fatal
hardware error
detected. Use 'show
post log' for more
info)
A non-fatal hardware error
was discovered during the
Power-on Self Test (POST)
phase of startup.
Enter the
show post log
command to investigate.
(A3005.0001–000C)
(
value
voltage sensor
shows
value
V - ALARM
SET)
A switch voltage sensor is
experiencing an out-of-range
voltage condition.
Contact your authorized
maintenance provider.
(A3006.0001–000C)
(
value
voltage sensor
shows
value
V - ALARM
SET)
An out-of-range voltage
condition has occurred.
Contact your authorized
maintenance provider.
Table 4
Alarm events and recommended action (Continued)
Icon
Event ID and message
Description
Action