• Issue: Some entries in the SMU and CLI are not localized properly for all languages. • Workaround: HP is continually updating localized content. • Issue: Some configuration changes under heavy I/O may return a communication error. • Workaround: Retry configuration changes during a period of lower I/O. • Issue: Some cached data in the browser may not be updated while navigating through the SMU. • Workaround: Press CTR + F5 to refresh or log out and back into the SMU. • Issue: The tree view for a vdisk in SMU may not function properly. • Workaround: Click the ++ symbol at the top of the tree view. This refreshes the screen and enables the tree view. • Issue: In single controller mode, some event log descriptions can indicate a second controller. • Workaround: These messages can be safely ignored. • Issue: During drive firmware upgrade, all volumes are taken offline to preserve data integrity. • Workaround: Plan drive firmware updates during a maintenance window. • Issue: In an HP c-Class BladeSystem environment, VMWare may fail I/O during failover operations. • Workaround: The VMWare kernel parameter ResetOnFailover must be set to 0 in order for array failover to work properly. • Issue: The serial number for a volume returned by the SMU and CLI does not match the serial number returned by VPD data. • Workaround: Serial numbers are shown in different formats. The last 16 digits of the serial number are unique for each volume and match between the CLI, SMU, and VPD data. • Issue: You can not create volumes for OpenVMS using the Provisioning Wizard or Create Volume Set pages of the SMU. • Workaround: Volumes for OpenVMS may only be created using the Create Volume page of the SMU. • Issue: If an error occurs before the provisioning wizard is complete then partial commits of configuration changes will be made. The provisioning wizard cannot be used to complete the configuration changes. • Workaround: Use the Create Volume Set and Default Mapping pages of the SMU to complete the configuration. Supersedes history Firmware Version M113R11 M112R14-03 M112R14-02 M111R06-07 M111R06-04 M111R06 M110R28-02 M110R28 M110R25 Effective date February 2012 Release date February 2012 August 2011 May 2011 October 2010 August 2010 August 2010 April 2010 March 2010 December 2009 Supersedes history 17
![](/manual_guide/products/hewlettpackard-msa2312i-hp-2000-g2-modular-smart-array-controller-firmware-m113r10-release-notes-508849014-2012-195fe40/17.png)