• The controller crashed when I/O restarted on vdisks that came online after drives that were removed earlier were reinstalled. • The incorrect speed was reported for 3Gbps drives. • When both SAS paths to a drive briefly disappeared, the drives were dropped. • In large systems with many cascaded drive enclosures, POST stalled during the SAS topology initialization. • Prevent repeated crashes and reboots during offline initialization of vdisk. • Expanded online help information available about expanding vdisks. • An email address greater than 31 characters crashed the controller. • An NTP time offset caused the time on the controller to be set incorrectly. • Added an additional prompt when expanding vdisks. • In HP SIM, the status of a single-controller array was errantly reported as Degraded (instead of OK) with the one I/O module installed. • After adding a drive enclosure to a system and performing a rescan, the ID number associated with the drive enclosures was incorrect. • Events for unused phy devices were written to the event logs. • Boot time was not accurately reported in the event logs. • Changed the power supply LED behavior for under-voltage conditions. The LED illuminates solid amber during an under-voltage condition, but will now remain illuminated even after the current returns to within range, until the power supply is replaced or power cycled. • The power supply module lost track of the reset state. • Different power supply and I/O module statuses were reporting on the two controllers in a dual-controller system. • After a firmware update, drives in enclosures 1 and 3 were classified as Unknown. • An I/O timeout on some drives caused the drives to go down and the vdisk to go offline. • Dual-port drives in attached drive enclosures became single ported or were marked as failed when a cable was disconnected. • The temperature for warnings on I/O Modules has been changed as follows: Critical=68 degrees Celcius (154.4 degrees Farenheit); Warning=63 degrees Celcius (145.4 degrees Farenheit). • A controller failed to start up when drives were missing from a vdisk. • When clearing metadata from multiple drives, the vdisk was quarantined. • Bad Block Relocation was erroneously performed on a drive other than the one that generated the medium error. This caused the erroneously used drive to later fail. • Updated all Japanese language files. • SMU-specific enhancements and fixes: ◦ Added the Send Test Notification button. ◦ Incorporated multiple improvements and corrections in the Japanese SMU. ◦ Improved the LUN number limit check. ◦ When scheduling a snapshot, if the prefix name is too long, an error message was not generated. ◦ Even after a temporary license expired, a message stating that several days remained in the trial period was displayed. ◦ The Volume Copy Now option was not working. 6 Enhancements and fixes