HP StorageWorks MSA2312fc HP StorageWorks 2312fc and 2324fc Modular Smart Arra - Page 45
Are both drive module LEDs off (Online/Activity and Fault/UID)?
View all HP StorageWorks MSA2312fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Are both drive module LEDs off (Online/Activity and Fault/UID)? Answer Yes Possible Reasons • There is no power. • The drive is offline. • The drive is not configured. Actions • Check that the drive is fully inserted and latched in place, and that the enclosure is powered on. Is the drive module Fault/UID LED blinking amber? Answer No, but the Online/Activity LED is blinking. Possible Reasons The drive is rebuilding. Actions No action required. NOTE: Do not remove a drive that is rebuilding. Removing a drive might terminate the current operation and cause data loss. Yes, and the The drive is offline. A predictive Online/Activity LED is off. failure alert may have been received for this device. Yes, and the Online/Activity LED is blinking. The drive is active, but a predictive failure alert may have been received for this device. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. Is a connected host port's Host Link Status LED off? Answer No Yes Possible Reasons System functioning properly. The link is down. Actions No action required. • Check cable connections. • Reseat cables. • Replace cables. • In SMU, review the event logs for indicators of a specific fault in a host data path component. HP 2312fc and 2324fc Modular Smart Array user guide 45