HP StorageWorks MSA2312fc HP StorageWorks 2312fc and 2324fc Modular Smart Arra - Page 45

Are both drive module LEDs off (Online/Activity and Fault/UID)?

Page 45 highlights

Are both drive module LEDs off (Online/Activity and Fault/UID)? Answer Yes Possible Reasons • There is no power. • The drive is offline. • The drive is not configured. Actions • Check that the drive is fully inserted and latched in place, and that the enclosure is powered on. Is the drive module Fault/UID LED blinking amber? Answer No, but the Online/Activity LED is blinking. Possible Reasons The drive is rebuilding. Actions No action required. NOTE: Do not remove a drive that is rebuilding. Removing a drive might terminate the current operation and cause data loss. Yes, and the The drive is offline. A predictive Online/Activity LED is off. failure alert may have been received for this device. Yes, and the Online/Activity LED is blinking. The drive is active, but a predictive failure alert may have been received for this device. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. Is a connected host port's Host Link Status LED off? Answer No Yes Possible Reasons System functioning properly. The link is down. Actions No action required. • Check cable connections. • Reseat cables. • Replace cables. • In SMU, review the event logs for indicators of a specific fault in a host data path component. HP 2312fc and 2324fc Modular Smart Array user guide 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

HP 2312fc and 2324fc Modular Smart Array user guide
45
Are both drive module LEDs off (Online/Activity and Fault/UID)?
Is the drive module Fault/UID LED blinking amber?
Is a connected host port’s Host Link Status LED off?
Answer
Possible Reasons
Actions
Yes
There is no power.
The drive is offline.
The drive is not configured.
Check that the drive is fully inserted
and latched in place, and that the
enclosure is powered on.
Answer
Possible Reasons
Actions
No, but the
Online/Activity LED
is
blinking
.
The drive is rebuilding.
No action required.
NOTE:
Do not remove a drive that is
rebuilding. Removing a drive might
terminate the current operation and
cause data loss.
Yes, and the
Online/Activity LED
is
off
.
The drive is offline. A predictive
failure alert may have been
received for this device.
Check the event log for specific
information regarding the fault.
Isolate the fault.
Contact an authorized service
provider for assistance.
Yes, and the
Online/Activity LED
is
blinking
.
The drive is active, but a
predictive failure alert may have
been received for this device.
Check the event log for specific
information regarding the fault.
Isolate the fault.
Contact an authorized service
provider for assistance.
Answer
Possible Reasons
Actions
No
System functioning properly.
No action required.
Yes
The link is down.
Check cable connections.
Reseat cables.
Replace cables.
In SMU, review the event logs for
indicators of a specific fault in a
host data path component.