HP StorageWorks P2000 HP StorageWorks P2000 G3 MSA System FC User Guide (59033 - Page 38

If you cannot your access your system for at least three minutes, after changing the, IP address

Page 38 highlights

.Table 5 Terminal emulator display settings Parameter Value Terminal emulation mode VT-100 or ANSI (for color support) Font Terminal Translations None Columns 80 Table 6 Terminal emulator connection settings Parameter Connector Value COM1 (typically) Baud rate 115,200 Data bits 8 Parity None Stop bits 1 Flow control None 4. In the terminal emulator, connect to controller A. 5. Press Enter to display the CLI prompt (#). 6. At the prompt, type the following command to set the values you obtained in Step 1 for each Network port, first for controller A and then for controller B: set network-parameters ip address netmask netmask gateway gateway controller a|b where: • address is the IP address of the controller • netmask is the subnet mask • gateway is the IP address of the subnet router • a|b specifies the controller whose network parameters you are setting For example: # set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 controller a # set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 193.168.0.10 controller b 7. Type the following command to verify the new IP addresses: show network-parameters Network parameters, including the IP address, subnet mask, and gateway address are displayed for each controller. 8. Use the ping command to verify network connectivity. For example: # ping 192.168.0.10 (gateway) Info: Pinging 192.168.0.10 with 4 packets. Success: Command completed successfully. - The remote computer responded with 4 packets. 9. In the host computer's command window, type the following command to verify connectivity, first for controller A and then for controller B: ping controller-IP-address If you cannot your access your system for at least three minutes after changing the IP address, your network might require you to restart the Management Controller(s) using the serial CLI. When you restart a Management Controller, communication with it is temporarily lost until it successfully restarts. 38 Installing the enclosures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

38
Installing the enclosures
.
4.
In the terminal emulator, connect to controller A.
5.
Press Enter to display the CLI prompt (#).
6.
At the prompt, type the following command to set the values you obtained in Step 1 for each Network
port, first for controller A and then for controller B:
set network-parameters ip
address
netmask
netmask
gateway
gateway
controller a|b
where:
address
is the IP address of the controller
netmask
is the subnet mask
gateway
is the IP address of the subnet router
a|b
specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway
193.168.0.10 controller b
7.
Type the following command to verify the new IP addresses:
show network-parameters
Network parameters, including the IP address, subnet mask, and gateway address are displayed for
each controller.
8.
Use the
ping
command to verify network connectivity.
For example:
# ping 192.168.0.10 (gateway)
Info: Pinging 192.168.0.10 with 4 packets.
Success: Command completed successfully. - The remote computer responded with 4
packets.
9.
In the host computer's command window, type the following command to verify connectivity, first for
controller A and then for controller B:
ping controller-
IP-address
If you cannot your access your system for at least three minutes
after changing the
IP address
, your network might require you to restart the Management Controller(s) using the serial
CLI. When you restart a Management Controller, communication with it is temporarily lost until it
successfully restarts.
Table 5
Terminal emulator display settings
Parameter
Value
Terminal emulation mode
VT-100 or ANSI (for color support)
Font
Terminal
Translations
None
Columns
80
Table 6
Terminal emulator connection settings
Parameter
Value
Connector
COM1 (typically)
Baud rate
115,200
Data bits
8
Parity
None
Stop bits
1
Flow control