HP Surestore 160ex Optical Drive and Library SCSI-2 Command Reference - Page 281
Unexpected ID value was detected, A detected ID sector number was greater than
View all HP Surestore 160ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 281 highlights
Table A-5 Drive Error Codes Internal Error Codes ODC Error Codes Code (hex.) Description 44 Cannot proceed with error correction because the syndrome buffer was filled 45 Cannot correct the error bytes within the time of one sector 46 A write data transfer to the encoder was too short 47 A write data transfer to the encoder was too long 48 Unexpected sequence of the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware sequence occurred in the ODC chip 50 Asynchronous interrupt of the DSP was detected 51 Unexpected ID value was detected 52 Both unexpected and expected ID value detected on one track 54 Target sector was passed before the current position was detected 57 A detected ID sector number was greater than the maximum sector number 70 A Parameter List was not prepared 71 A sector number of the Parameter List was greater than the maximum sector number 72 A sector count of the Parameter List is set to 0 in the W/R/S 73 Undefined condition is set in the DTS, DLS command 7D Setup command was issued while executing the Identify operation 7E A command was issued while executing another command 7F Undefined command was issued A-18 Appendix A