HP Surestore 160ex Optical Drive and Library SCSI-2 Command Reference - Page 324
Table B-11, Micro-Move Error Codes For the 40fx, 80ex, 125ex, and 220mx, models ONLY, Error Code
View all HP Surestore 160ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 324 highlights
Autochanger Error Codes Table B-11 Autochanger Error Codes Jukebox Micro-Move Error Codes Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code Description (hex.) 12 Diagnose FRU failed. 13 Initial recovery failed. 14 Find home failed. 15 Picker initialization failed. 16 Cartridge-in-path beams are blocked. 20 Failed to find hard stop at end of flip. 22 Failed to see sensor close at the end of translate. 23 Failed to move to the vertical position needed to engage the translate pin. 24 Failed to see sensor close at the start of translate. 25 Failed to see height sensor re-open after closing at the start of a translate. 28 The translate distance was too long. 29 The translate distance was too short. 31 Failed while checking for cartridge in a drive. 32 Failed to find a hard stop returning cartridge to storage after testing for presence of cartridge. 33 Failed while checking for cartridge in a storage slot. 34 Failed while checking for cartridge in the Picker. 35 Failed while checking for cartridge in the mailslot. 36 Could not free fingers after testing for a cartridge in a drive. 38 Failed to verify that cartridge exists after insert. Appendix B B-37