HP Surestore 80ex Optical Drive and Library SCSI-2 Command Reference - Page 328
Table B-12, Diagnostic Tests EXCEPT for models 40fx, 80ex, 125ex, and, 220mx, Front Panel, Test Name
View all HP Surestore 80ex manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 328 highlights
Autochanger Error Codes Table B-12 Autochanger Error Codes Jukebox Micro-Move Error Codes Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx) No. Front Panel Description Test Name 12 VERTICAL TEST Moves the disk transport mechanism up and down the full length of the rail. Returns PASS/FAIL. No cartridges required. 13 TRANSLATE Reports ON or OFF. Looks at translate SENSOR sensor. 14 FLIP TEST Makes a combination of moves with a PASS/ FAIL result. It does several flips at various locations. No optical disks are required. 15 MAGAZINE IO Makes a combination of moves with a PASS/ FAIL result. It moves an optical disk from a randomly-chosen full to a randomly-chosen empty slot, with a random flip. It then moves the disk back to its original storage slot with its original orientation. This test displays "FAIL" if there are no disks in the jukebox or if all storage slots are full. The drives and mailslot must be empty. 16 DRIVE IO Makes a combination of moves with a PASS/ FAIL result. It moves an optical disk from a randomly-chosen full slot to a randomlychosen drive, with a random flip. It then moves the cartridge back to its original slot with its original orientation. This test displays if there are no disks in the jukebox or if all storage slots are full. The drives and mailslot must be empty. Appendix B B-41