HP Vectra XU 6/XXX HP Vectra XU 6/xxx and VT 6/xxx PCs - Technical Reference M - Page 51
Machine-Dependent Actions
View all HP Vectra XU 6/XXX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
SCA34 • Re-configure your accessory board. Check your manual and Setup to see which resources are used by the internal devices. Machine-Dependent Actions: SCA35 • Replace the memory modules as follows: Error code Replace module in: 201A Slot A or Slot B 202A Slot C or Slot D 204A Slot E or Slot F 208A Slot G or Slot H SCA36 • Replace the memory modules as follows: Error code Replace module in: 4F01 Slot A 4F02 Slot B 4F03 Slot C 4F04 Slot D 4F05 Slot E 4F06 Slot F 4F07 Slot G 4F08 Slot H SCA37 • The memory error that was detected during the last session has been corrected. Run Setup to clear the error. • If this message appears in the future again with the same error code, you should replace a memory module in that location: Error code Replace module in: 201B Slot A1 or Slot A2 202B Slot B1 or Slot B2 204B Slot C1 or Slot C2 208B Slot D1 or Slot D2 SCA38 • One of the memory modules must be replaced. The following table indicates the location: Error code Replace module in: 201C Slot A1 or Slot A2 202C Slot B1 or Slot B2 204C Slot C1 or Slot C2 208C Slot D1 or Slot D2 • Run Setup to clear the error.