Hikvision IDS-2CD7AC5G0-IZHSY 2.8-12mm User Manual - Page 51
Set Object Removal Detection
View all Hikvision IDS-2CD7AC5G0-IZHSY 2.8-12mm manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
iDS-2CD7xxG0-xxxxx Network Bullet Camera User Manual Figure 6-8 Set Rule 5. Optional: You can set the parameters of multiple areas by repeating the above steps. 6. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings, refer to Linkage Method Settings. 7. Click Save. Set Object Removal Detection Detects whether objects are removed from a pre-defined detection region such as exhibits on display. If it occurs, the device can take linkage actions and the staff can take measures to reduce property loss. Steps 1. Go to Configuration → Event → Smart Event → Object Removal Detection. 2. Check Enable. 3. Select a Region. For the region settings, see Draw Area. 4. Set the rule. • Sensitivity (Range [1-100]): Percentage of body part of an acceptable target that leaves the predefined region. Sensitivity = 100 - S1/ST*100 S1 is the target body part that leaves the pre-defined region. ST is the complete target body. EXAMPLE: If you set the value as 60, a target will be counted as a removed object only when 40 percent body part of the target leaves the region. • Threshold: Range [5-100s], the threshold for the time of the objects removed from the region. If you set the value as 10, alarm is triggered after the object disappears from the region for 10s. UM iDS-2CD7xxG0-xxxxx 021021NA 51