Hitachi CP-X3010N User Manual - Page 48

Communication Type

Page 48 highlights

OPTION menu Item SERVICE (continued) Description COMMUNICATION TYPE Select the communication type for transmission via the CONTROL port. NETWORK BRIDGE ó OFF NETWORK BRIDGE: Select this type, if it is required to control an external device as a network terminal, via this projector from the computer. The CONTROL port doesn't accept RS-232C commands.(Controlling the external device via the projector (using the NETWORK BRIDGE function) of the User's Manual - Network Guide) OFF: Select this mode to receive RS-232C commands using the CONTROL port. • OFF is selected as the default setting. • When you select the NETWORK BRIDGE, check the item, TRANSMISSTION METHOD (below). SERIAL SETTINGS Select the serial communication condition for the CONTROL port. COMMUNICATION (continued) BAUD RATE 4800bps ó 9600bps ó 19200bps ó 38400bps PARITY NONE ó ODD ó EVEN (continued on next page) • The BAUD RATE is fixed to 19200bps and PARITY is fixed NONE when the COMMUNICATION TYPE is set to OFF (above). TRANSMISSION METHOD Select the transmission method for communication by the NETWORK BRIDGE from the CONTROL port. HALF-DUPLEX ó FULL-DUPLEX HALF-DUPLEX: This method lets the projector make two way communication, but only one direction, either transmitting or receiving data, is allowed at a time. FULL-DUPLEX: This method lets the projector make two way communication, transmitting and receiving data at the same time. • HALF-DUPLEX is selected as the default setting. • When you select HALF-DUPLEX, check the items, RESPONSE LIMIT TIME and BYTES INTERVAL TIMEOUT (49). 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

48
OPTION menu
Item
Description
SERVICE
(continued)
COMMUNICATION
(continued)
COMMUNICATION TYPE
Select the communication type for transmission via
the
CONTROL
port.
NETWORK BRIDGE
ó
OFF
NETWORK BRIDGE:
Select this type, if it is
required to control an external device as a network
terminal, via this projector from the computer.
The
CONTROL
port doesn't accept RS-232C
commands.(
Controlling the external device
via the projector (using the NETWORK BRIDGE
function) of the User’s Manual - Network Guide
)
OFF
: Select this mode to receive RS-232C
commands using the
CONTROL
port.
OFF is selected as the default setting.
• When you select the NETWORK BRIDGE, check
the item, TRANSMISSTION METHOD
(
below
)
.
SERIAL SETTINGS
Select the serial communication condition for the
CONTROL
port.
BAUD RATE
4800bps
ó
9600bps
ó
19200bps
ó
38400bps
PARITY
NONE
ó
ODD
ó
EVEN
The BAUD RATE is fixed to 19200bps and PARITY
is fixed NONE when the COMMUNICATION TYPE
is set to OFF
(
above
)
.
TRANSMISSION METHOD
Select the transmission method for communication by
the NETWORK BRIDGE from the
CONTROL
port.
HALF-DUPLEX
ó
FULL-DUPLEX
HALF-DUPLEX: This method lets the projector
make two way communication, but only one
direction, either transmitting or receiving data, is
allowed at a time.
FULL-DUPLEX: This method lets the projector
make two way communication, transmitting and
receiving data at the same time.
• HALF-DUPLEX is selected as the default setting.
• When you select HALF-DUPLEX, check the items,
RESPONSE LIMIT TIME and BYTES INTERVAL
TIMEOUT
(
49
)
.