Page 12 highlights

Configuring and Controlling the Projector via a Web Browser Alert Settings (Continued) The Alert Items are shown below. Setting Item Alarm Time Description Configures the time to alert. (Only Lamp Time Alarm and Filter Time Alarm.) SNMP Trap Send Mail Mail Subject Click the [Enable] check box to enable SNMP trap alerts. Click the [Enable] check box to enable e-mail alerts. (Except Cold Start and Authentication Failure.) Configures the subject line of the e-mail to be sent. The length of the subject line can be up to 255 alphanumeric characters. (Except Cold Start and Authentication Failure.) Mail Text Configures the text of the e-mail to be sent. The length of the text can be up to 1024 alphanumeric characters. (Except Cold Start and Authentication Failure.) Click the [Apply] button to save the settings. NOTE • The trigger of Filter Error e-mail is depending on the FILTER MESSAGE setting in the SERVICE item of the OPTION menu which defines the period until filter message is displayed on the projector screen. The e-mail will be sent when the filter timer exceeds 50, 100, 200, 300, 400, 500, 600, 700 or 800 hours based on the configuration. No notification e-mail will be sent if the FILTER MESSAGE is set to TURN OFF. ("OPTION menu" section of the User's Manual - Operating Guide) • Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of the lamp timer. When the lamp hour exceeds this threshold that is configured through the Web page, the e-mail will be sent out. • Filter Time Alarm is defined as a threshold for e-mail notification (reminder) of the filter timer. When the filter hour exceeds this threshold, the e-mail will be sent out. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

±²
Alert Settings (Continued)
Setting Item
Description
Alarm Time
Configures the time to alert.
(Only Lamp Time Alarm and Filter Time Alarm.)
SNMP Trap
Click the
[Enable]
check box to enable SNMP trap alerts.
Send Mail
Click the
[Enable]
check box to enable e-mail alerts.
(Except
Cold Start
and
Authentication Failure
.)
Mail Subject
Configures the subject line of the e-mail to be sent.
The length of the subject line can be up to 255 alphanumeric
characters.
(Except
Cold Start
and
Authentication Failure
.)
Mail Text
Configures the text of the e-mail to be sent.
The length of the text can be up to 1024 alphanumeric
characters.
(Except
Cold Start
and
Authentication Failure
.)
The Alert Items are shown below.
• The trigger of Filter Error e-mail is depending on the FILTER
MESSAGE setting in the SERVICE item of the OPTION menu which defines
the period until filter message is displayed on the projector screen. The e-mail
will be sent when the filter timer exceeds 50, 100, 200, 300, 400, 500, 600, 700
or 800 hours based on the configuration. No notification e-mail will be sent if the
FILTER MESSAGE is set to TURN OFF. (
"OPTION menu" section of the User's
Manual - Operating Guide
)
• Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of
the lamp timer. When the lamp hour exceeds this threshold that is configured
through the Web page, the e-mail will be sent out.
• Filter Time Alarm is defined as a threshold for e-mail notification (reminder)
of the filter timer. When the filter hour exceeds this threshold, the e-mail will be
sent out.