Hitachi CPX305 Network Guide - Page 25

SNMP Settings

Page 25 highlights

Projector Management using SNMP Projector Management using SNMP The SNMP (Simple Network Management Protocol) enables to manage the projector information, which is a failure or warning status, from the computer on the network. The SNMP management software will be required on the computer to use this function. NOTE • It is recommended that SNMP functions be carried out by a network administrator. • SNMP management software must be installed on the computer to monitor the projector via SNMP. SNMP Settings Configure the following items via a web browser to use SNMP. Example: If the IP address of the projector is set to 192.168.1.10: 1) Enter "http://192.168.1.10/" into the address bar of the web browser. 2) Enter the Administrator ID and password and click [Logon]. 3) Click [Port Settings] on the main menu. 4) Click the [Enable] check box to open the SNMP Port. Set the IP address to send the SNMP trap to when a Failure/Warning occurs. NOTE • A Network Restart is required after the SNMP Port configuration settings have been changed. Click [Network Restart] and configure the following items. 5) Click [Security Settings] on the main menu. 6) Click [SNMP] and set the Community Name on the screen that is displayed. NOTE • A Network Restart is required after the Community Name has been changed. Click [Network Restart] and configure the following items. 7) C onfigure the settings for Trap transmission of Failures/Warnings. Click [Alert Settings] on the main menu and select the Failure/Warning item to be configured. 8) Click the [Enable] check box to send out the SNMP trap for Failures/Warnings. Clear the [Enable] check box when SNMP trap transmission is not required. 9) Click the [Apply] button to save the settings. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

25
Projector Management using SNMP
The SNMP (Simple Network Management Protocol) enables to manage the
projector information, which is a failure or warning status, from the computer on
the network. The SNMP management software will be required on the computer
to use this function.
• It is recommended that SNMP functions be carried out by a network
administrator.
• SNMP management software must be installed on the computer to monitor
the projector via SNMP.
NOTE
SNMP Settings
Configure the following items via a web browser to use SNMP.
Example: If the IP address of the projector is set to 192.168.1.10:
• A Network Restart is required after the
SNMP Port
configuration
settings have been changed. Click
[Network Restart]
and configure the
following items.
NOTE
5) Click
[Security Settings]
on the main menu.
6) Click
[SNMP]
and set the
Community Name
on the screen that is displayed.
• A Network Restart is required after the
Community Name
has been
changed. Click
[Network Restart]
and configure the following items.
NOTE
7) Configure the settings for Trap transmission of Failures/Warnings. Click
[Alert Settings]
on the main menu and select the Failure/Warning item to be
configured.
´) Click the
[Enable]
check box to send out the SNMP trap for Failures/Warnings.
Clear the
[Enable]
check box when SNMP trap transmission is not required.
9) Click the
[Apply]
button to save the settings.
±) Enter
into the address bar of the web browser.
2) Enter the Administrator ID and password and click
[Logon]
.
3) Click
[Port Settings]
on the main menu.
4) Click the
[Enable]
check box to open the
SNMP Port
.
Set the IP address to send the SNMP trap to when a
Failure/Warning occurs.
Projector Management using SNMP