Hitachi ED-A100 User Manual - Page 72
Phenomena that may be easy to be mistaken for machine defects continued
UPC - 050585151338
View all Hitachi ED-A100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Troubleshooting Phenomena that may be easy to be mistaken for machine defects (continued) Phenomenon Cases not involving a machine defect Reference page The signal cables are not correctly connected. Correctly connect the audio cables. 10 The MUTE function is working. Restore the sound pressing MUTE or VOLUME button on 18 Sound does not the remote control. come out. The volume is adjusted to an extremely low level. Adjust the volume to a higher level using the menu function 18 or the remote control. The AUDIO/SPEAKER setting is not correct. Correctly set the AUDIO/SPEAKER in SETUP Menu. 37 The lens door is not fully opened. Turn the projector off, and then turn it on again to make sure that the door is opened correctly. 16, 66 The signal cables are not correctly connected. Correctly connect the connection cables. 10 The brightness is adjusted to an extremely low level. No pictures are Adjust BRIGHTNESS to a higher level using the menu displayed. function. 27, 28 The computer cannot detect the projector as a plug and play monitor. Make sure that the computer can detect a plug and play 11 monitor using another plug and play monitor. The BLANK screen is displayed. Press BLANK button on the remote control. 23 (continued on next page) 72