Honeywell 1900GSR-2 User Guide - Page 145
Full ASCII, Code 39 Code
View all Honeywell 1900GSR-2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off. NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N SI $O DLE $P DC1 $Q DC2 $R DC3 $S DC4 $T NAK $U SYN $V ETB $W CAN $X EM $Y SUB $Z ESC %A FS %B GS %C RS %D US %E SP SPACE 0 ! /A 1 " /B 2 # /C 3 $ /D 4 % /E 5 & /F 6 ' /G 7 ( /H 8 ) /I 9 * /J : + /K ; , /L < -- = .. > / /O ? 0@ 1A 2B 3C 4D 5E 6F 7G 8H 9I /Z J %F K %G L %H M %I N %J O %V P AQ BR CS DT EU FV GW HX IY JZ K[ L\ M] N^ O_ P' Qa Rb Sc Td Ue Vf Wg Xh Yi Zj %K k %L l %M m %N n %O o %W p +P +A q +Q +B r +R +C s +S +D t +T +E u +U +F v +V +G w +W +H x +X +I y +Y +J z +Z +K { %P +L | %Q +M } %R +N ~ %S +O DEL %T Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Full ASCII On * Full ASCII Off Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Barcodes on page A-6), 7 - 9