Honeywell 1900GSR-2 User Guide - Page 88
Auto Reconnect Mode, Event
View all Honeywell 1900GSR-2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Auto Reconnect Mode Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without user intervention. Default = Auto Reconnect On. * Auto Reconnect On Auto Reconnect Off Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off. The table below shows the results of the Auto Reconnect On and Off settings: Event Scanner out of range Base or Access point reset (firmware upgrade or power cycle) Auto Reconnect On Relink occurs automatically. If maximum number of link attempts is unsuccessful, then the scanner must be relinked by either pulling the trigger, placing the scanner in the base, or scanning the Access Point linking bar code. (See Maximum Link Attempts on page 3-29.) Scanner behaves as if out of range. Auto Reconnect Off The scanner is relinked by pulling the trigger, or scanning the Access Point linking bar code. No attempt to relink made while base or Access Point is powered off. Trigger must be pulled to initiate relinking. 3 - 28