Good Read Delay, User-Specified Good Read Delay, Trigger Modes, Manual/Serial Trigger, Read Time-Out
![]() |
View all Honeywell 3800gPDF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Good Read Delay This sets the minimum amount of time before the imager can read another bar code. Default = No Delay. * No Delay Short Delay (500 ms) Medium Delay (1000 ms) Long Delay (1500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. User-Specified Good Read Delay Trigger Modes Manual/Serial Trigger You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 11-4). When in manual trigger mode, the imager scans until a bar code is read, or until the trigger is released. When in serial mode, the imager scans until a bar code has been read or until the deactivate command is sent. In serial mode, the imager can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows). * Manual/Serial Trigger Read Time-Out Use this selection to set a time-out (in milliseconds) of the imager's trigger when using serial commands to trigger the imager. Once the imager has timed out, you can activate the imager either by pressing the trigger or using a serial trig- 3 - 3