4: COMPONENTS K J I H F E A B L M N G C D FIGURE 4-1: Honeywell Portable Electrical Generator Controls and Components (HW5500EL Model Illustrated) A-Power Control Center Electrical Outlets • 125VAC 20 Amp Duplex (NEMA 5-20R) outlets to connect 120V appliances to generator for power. • 125/250VAC 30 Amp Twist-Lock (NEMA L14-30R) outlet (on select models) can be used to power appliances using appropriate (NEMA L14-30P) power cord (with select models) or connect a transfer switch (not included) to a building's main electrical system for backup power. Breakers Protects circuits from damage caused by overload or short-circuit by stopping the flow of electricity from the generator to the appliance. Master circuit breaker controls power to all outlets. If there is no power at outlets, see TROUBLESHOOTING, page 8-1. Set Tripped HW3000 / HW3000L models only: • 15-amp circuit breaker (left outlet) • 10-amp circuit breaker (right outlet) Ground Terminal Connects generator to ground wire for grounding protec- tion. E-Engine Control Switch Control used to start and stop the engine ignition system. • START-Starts generator engine (electric start models) • RUN-Prepares engine to start (manual start models); Indicates engine is currently running (electric start models) • STOP-Stops generator engine by inhibiting ignition F-Fuel Shut-off Valve Controls flow of fuel from fuel tank to carburetor. G-Recoil Starter Handle Provides means to manually start engine, if needed. H-Air Cleaner Assembly Removes dust from engine intake air. I- Choke Control Controls choke valve. Choke control must be moved to ON position when starting a cold engine. J-Fuel Cap Provides a secure seal on fuel tank. K-Fuel Gage Indicates level of fuel currently in fuel tank. L-Muffler Equipped with Spark Arrestor Provides outlet for engine exhaust. Prevents sparks and other combustible materials from escaping generator. CAUTION WARNING Generator must be grounded to prevent electrical shock from faulty appliances. Muffler reaches temperatures that can cause serious burns if touched. NEVER touch hot surfaces. B-Battery Tray and Battery (Electric start models only) Provides power for electric start feature. C-Oil Fill Dipstick Seals off engine oil fill hole and provides indicator for engine oil level. M-Spark Plug Cap (Wire) Delivers voltage to spark plug. When spark plug needs service, cap must be removed. N-Carbon Canister (Model numbers ending in "L" only) Reduces hydrocarbon emissions. D-Oil Drain Screw Allows engine oil to drain from generator. Honeywell Portable Electrical Generator Service Manual www.honeywellgenerators.com 4-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Honeywell Portable Electrical Generator Service Manual
www.honeywellgenerators.com
4-1
4: COMPONENTS
A—Power Control Center
Electrical Outlets
125VAC 20 Amp Duplex (NEMA 5-20R) outlets to connect
120V appliances to generator for power.
125/250VAC 30 Amp Twist-Lock (NEMA L14-30R) outlet
(on select models) can be used to power appliances
using appropriate (NEMA L14-30P) power cord (with
select models) or connect a transfer switch (
not
included
) to a building’s main electrical system for
backup power.
Breakers
Protects circuits from damage caused by
overload or short-circuit by
stopping the flow
of electricity from the generator to the appli-
ance. Master circuit breaker controls power
to all outlets. If th
ere is no power at outlets,
see TROUBLESHOOTING, page 8-1.
HW3000 / HW3000L models only:
15-amp circuit breaker (left outlet)
10-amp circuit breaker (right outlet)
Ground Terminal
Connects generator to ground wire for grounding protec-
tion.
B—Battery Tray and Battery (Electric start models only)
Provides power for electric start feature.
C—Oil Fill Dipstick
Seals off engine oil fill hole and provides indicator for
engine oil level.
D—Oil Drain Screw
Allows engine oil to drain from generator.
E—Engine Control Switch
Control used to start and stop the engine ignition system.
START
—Starts generator engine (electric start models)
RUN
—Prepares engine
to start
(manual start models);
Indicates engine is currently running (electric start mod-
els)
STOP
—Stops generator engine by inhibiting ignition
F—Fuel Shut-off Valve
Controls flow of fuel from fuel tank to carburetor.
G—Recoil Starter Handle
Provides means to manually start engine, if needed.
H—Air Cleaner Assembly
Removes dust from engine intake air.
I— Choke Control
Controls choke valve. Choke control must be
moved
to
ON position when starting a cold engine.
J—Fuel Cap
Provides a secure seal on fuel tank.
K—Fuel Gage
Indicates level of fuel currently in fuel tank.
L—Muffler Equipped with Spark Arrestor
Provides outlet for engine exhaust. Prevents sparks and
other combustible materials from escaping generator.
M—Spark Plug Cap (Wire)
Delivers voltage to spark plug. When spark plug needs
service, cap must be removed.
N—Carbon Canister (Model numbers ending in “L” only)
Reduces hydrocarbon emissions.
FIGURE 4-1:
Honeywell Portable Electrical Generator Controls and Components (HW5500EL Model Illustrated)
K
G
B
I
H
J
E
C
D
A
F
M
L
N
Generator must be grounded to prevent electrical
shock from faulty appliances.
Tripped
Set
CAUTION
Muffler reaches temperatures that can cause serious
burns if touched. NEVER touch hot surfaces.
WARNING