STARTING SYSTEM 9.8 STARTING SYSTEM A-ELECTRIC STARTER Attempt to crank engine by switching the engine control switch to the START position. Starter Solenoid Terminal Nut 6 N•m (4 lb. ft.) B B-WOODRUFF KEY After installing the flywheel, check to ensure the woodruff key is still in its slot on the crankshaft. C-SPARK PLUG LEAD Clamp securely to the crankcase with the two clamps. Check for cracked or damaged insulation; replace, if necessary. D-IGNITION COIL Pull spark plug lead and connect to spare. Check ignition for spark to ground. 10 N•m (7 lb. ft.) E-FLYWHEEL F-CLAMP G-CHARGING COIL ASSEMBLY Check for continuity. A G F C D E 9-8 www.honeywellgenerators.com Honeywell Portable Electrical Generator Service Manual
STARTING SYSTEM
9-8
www.honeywellgenerators.com
Honeywell Portable Electrical Generator Service Manual
9.8
STARTING SYSTEM
A—ELECTRIC STARTER
Attempt to crank engine by switching the
engine control switch to the START position.
Starter Solenoid Terminal Nut -
6 N•m (4 lb. ft.)
B—WOODRUFF KEY
After installing the flywheel, check to ensure
the woodruff key is still in its slot on the
crankshaft.
C—SPARK PLUG LEAD
Clamp securely to the crankcase with the
two clamps.
Check for cracked or damaged insulation;
replace, if necessary.
D—IGNITION COIL
Pull spark plug lead and connect to spare.
Check ignition for spark to ground.
10 N•m (7 lb. ft.)
E—FLYWHEEL
F—CLAMP
G—CHARGING COIL ASSEMBLY
Check for continuity.
D
B
C
A
E
F
G