HEPA Final filter How to clean Disconnect cleaner from electrical outlet. Do not operate cleaner without dirt cup or filters in place. 3-9 A What to buy When purchasing a new HEPA filter cartridge, ask for HOOVER part No. 93002360. Headlight replacement What to buy This cleaner uses a 13 volt, T-3 114 wedge base bulb, Hoover part No. 27313-107. 3-10 With fingers in slots, pull filter frame (A) straight out. Dirt and debris can be cleaned from the filter cartridge by brushing with the cleaner's combination tool. DO NOT RINSE OR WASH the HEPA filter cartridge. Slide back into position on cleaner. Removing lens Disconnect cleaner from electrical outlet. Press handle release pedal and place handle in low position. Using a Phillips screwdriver, remove the the screw as shown and lift off lens. 3-11 Installing bulb Pull old bulb straight out of socket. Push new bulb straight into socket until locked in place. Excessive force is not required. 3-12 Replacing lens Reposition lens and secure with the screw. Belt replacement The belts are located under the bottom plate of the cleaner and should be checked from time to time to be sure they are in good condition. The flat (wide) belt is described below; the other belt is described under "Agitator brush roll". When to replace Disconnect cleaner from electrical outlet. WARNING: Agitator brush roll can start suddenly. Unplug cleaner before turning it over. To check the flat belt, remove bottom plate as shown in "Replacing flat belt". Replace belt if it is stretched, cut or broken. What to buy To assure effective operation, use only genuine HOOVER belts with your cleaner. When purchasing a new belt, ask for Flat belt - HOOVER part No. 40201-271. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

With fingers in slots, pull filter frame
(A) straight out.
Dirt and debris can be cleaned from
the filter cartridge by brushing with
the cleaner’s combination tool.
DO
NOT RINSE OR WASH the HEPA
filter cartridge.
Slide back into position on cleaner.
Replacing lens
Reposition lens and secure with the
screw.
Belt replacement
The belts are located under the bot-
tom plate of the cleaner and should
be checked from time to time to be
sure they are in good condition.
The flat (wide) belt is described
below; the other belt is described
under “Agitator brush roll”.
When to replace
Disconnect cleaner from electrical
outlet. WARNING: Agitator brush
roll can start suddenly. Unplug
cleaner before turning it over.
To check the flat belt, remove bot-
tom plate as shown in “Replacing
flat belt”. Replace belt if it is
stretched, cut or broken.
What to buy
To assure effective operation, use
only genuine HOOVER belts with
your cleaner.
When purchasing a
new belt, ask for Flat belt -
HOOVER
part No. 40201-271
.
10
3-11
3-12
Installing bulb
Pull old bulb straight out of socket.
Push new bulb straight into socket
until locked in place.
Excessive force is not required.
Removing lens
Disconnect cleaner from electrical
outlet.
Press handle release pedal and
place handle in low position.
Using a Phillips screwdriver, remove
the the screw as shown and lift off
lens.
3-9
A
HEPA Final filter
How to clean
Disconnect cleaner from electrical
outlet. Do not operate cleaner
without dirt cup or filters in place.
3-10
What to buy
When purchasing a new HEPA
filter cartridge, ask for
HOOVER
part No. 93002360.
Headlight replace-
ment
What to buy
This cleaner uses a 13 volt, T-3 114
wedge base bulb,
Hoover part No.
27313-107
.