Hunter 25522 Owner's Manual - Page 7

attaching the lower switch housing, installing the light fixture, installing without the light

Page 7 highlights

3. Assemble the upper switch housing to the mounting plate using the three screws and lockwashers which you removed from the mounting plate. Tighten the screws securely. CAUTION: Make sure the upper switch housing is securely attached to the switch housing mounting plate. Failure to properly attach and tighten all three housing assembly screws could result in the switch housing and light fixture falling. attaching the lower switch housing 1. Connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly. See Figure 17. NOTE: Both plug connectors are polarized and will only fit together one way. Make sure that both connectors are properly aligned before connecting them together. Incorrect connection could cause improper operation and damage to the product. Lower Plug Connector Housing Assembly Screw Upper Switch Housing Upper Plug Connector Lower Switch Housing Figure 17 - Connecting the plug connectors 2. Place the lower switch housing assembly over the upper switch housing. Align the side screw holes in the upper and lower switch housings. Attach the lower switch housing to the upper switch housing with three #6-32 x 3/8" housing assembly screws. See Figure 17. installing the light fixture 1. Install the included CFL bulb. 2. Align the notches in the globe assembly with the bumps on the fitter. 3. Twist the globe assembly clockwise until it locks in place. 4. Be sure that the holes in the fitter cover and globe assembly align as shown in Figure 18. If they do not, remove the globe assembly and begin with step 2 in a different position. 7 Notch in Globe Assembly Fitter Fitter Cover Globe Assembly Figure 18 - Installing the globe assembly installing without the light fixture 1. Install the upper switch housing as shown in the attaching the upper switch housing section. 2. Disconnect the two single plug connectors in the lower switch housing. Place the dummy terminals (in the sack parts) on the end of each single plug connector. The female dummy terminal must be placed on the male plug connector and the male dummy terminal on the female plug connector. 3. Remove the fitter assembly from the lower switch housing by removing the two screws inside of the fitter as shown in Figure 19. Fitter Remove these screws Figure 19 - Removing the fitter assembly 4. Install the lower switch housing as shown in the attaching the lower switch housing section. 5. Install the cap and plug button as shown in Figure 20. Cap Plug Button Figure 20 - Installing the cap and plug button 41877-01 06/14/2007 © 2007 Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

41877-01
06/14/2007
© 2007 Hunter Fan Company
7
Lower Plug
Connector
Upper Switch
Housing
Upper Plug
Connector
Lower
Switch
Housing
Housing
Assembly
Screw
3.
Assemble the upper switch housing to the mounting plate
using the three screws and lockwashers which you removed
from the mounting plate. Tighten the screws securely.
CAUTION: Make sure the upper switch housing is se-
curely attached to the switch housing mounting plate. Fail-
ure to properly attach and tighten all three housing assem-
bly screws could result in the switch housing and light fix-
ture falling.
attaching the lower switch housing
1.
Connect the upper plug connector from the motor to the lower
plug connector in the lower switch housing assembly. See Fig-
ure 17.
NOTE: Both plug connectors are polarized and will only fit to-
gether one way. Make sure that both connectors are properly
aligned before connecting them together. Incorrect connec-
tion could cause improper operation and damage to the prod-
uct.
Figure 17 - Connecting the plug connectors
2.
Place the lower switch housing assembly over the upper switch
housing. Align the side screw holes in the upper and lower
switch housings. Attach the lower switch housing to the up-
per switch housing with three #6-32 x 3/8" housing assembly
screws. See Figure 17.
installing the light fixture
1.
Install
the included CFL bulb
.
2.
Align the notches in the globe assembly with the bumps on
the fitter.
3.
Twist the globe assembly clockwise until it locks in place.
4.
Be sure that the holes in the fitter cover and globe assembly
align as shown in Figure 18. If they do not, remove the globe
assembly and begin with step 2 in a different position.
Figure 18 - Installing the globe assembly
installing without the light fixture
1.
Install the upper switch housing as shown in the
attaching
the upper switch housing
section.
2.
Disconnect the two single plug connectors in the lower switch
housing. Place the dummy terminals (in the sack parts) on the
end of each single plug connector. The female dummy termi-
nal must be placed on the male plug connector and the male
dummy terminal on the female plug connector.
3.
Remove the fitter assembly from the lower switch housing by
removing the two screws inside of the fitter as shown in Figure
19.
Figure 19 - Removing the fitter assembly
4.
Install the lower switch housing as shown in the
attaching the
lower switch housing
section.
5.
Install the cap and plug button as shown in Figure 20.
Figure 20 - Installing the cap and plug button
Globe Assembly
Fitter
Fitter Cover
Notch in
Globe
Assembly
Fitter
Remove these screws
Cap
Plug Button