IBM 2019A1X Installation Guide - Page 23

Installing a management module, Attention, Notes

Page 23 highlights

The following server operating systems have USB support, which is required for the Remote Control feature: v Microsoft Windows Server 2003 v Microsoft Windows 2000 with Service Pack 4 or later v Red Hat Linux version 7.3 v SUSE LINUX version 8.0 v Novell NetWare 6.5 The management-module Web interface does not support double-byte character set (DBCS) languages. Installing a management module The following illustration shows how to install a management module in a BladeCenter unit. Your BladeCenter unit might differ from the illustrations in this document. When you install a management module, if the BladeCenter unit is not connected to a DHCP server on the network, it takes up to 3 minutes for the management module to use the default (static) IP address. Attention: To maintain proper system cooling, each module bay must contain either a module or a module filler. Management module Notes: 1. If you replace a standby management module, it must be of the same type as the active management module. 2. These instructions assume that the BladeCenter unit is connected to power. 3. After failover, you might need to wait as long as 5 minutes to establish a network connection to the management module. Some networks include switches, routers, and hubs which do not allow (or relay) an address Chapter 3. Installing a management module 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

The following server operating systems have USB support, which is required
for the Remote Control feature:
v
Microsoft Windows Server 2003
v
Microsoft Windows 2000 with Service Pack 4 or later
v
Red Hat Linux version 7.3
v
SUSE LINUX version 8.0
v
Novell NetWare 6.5
The management-module Web interface does not support double-byte
character set (DBCS) languages.
Installing a management module
The following illustration shows how to install a management module in a
BladeCenter unit. Your BladeCenter unit might differ from the illustrations in
this document.
When you install a management module, if the BladeCenter unit is not
connected to a DHCP server on the network, it takes up to 3 minutes for the
management module to use the default (static) IP address.
Attention:
To maintain proper system cooling, each module bay must contain
either a module or a module filler.
Management
module
Notes:
1.
If you replace a standby management module, it must be of the same type
as the active management module.
2.
These instructions assume that the BladeCenter unit is connected to power.
3.
After failover, you might need to wait as long as 5 minutes to establish a
network connection to the management module. Some networks include
switches, routers, and hubs which do not allow (or relay) an address
Chapter 3. Installing a management module