IBM 419452u Installation Guide - Page 56

listing

Page 56 highlights

Table 4. Abbreviated list of POST error codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action I9990305 An operating system was not found. 1. Make sure that a bootable operating system is installed. 2. Run the hard disk drive diagnostic tests. 3. Reseat the following components: a. Hard disk drive b. CD or DVD drive and cables c. (Trained service technician only) System board 4. Replace the components listed in step 3 one at a time, in the order shown, restarting the server each time. I9990650 AC power has been restored. 1. Check the power cables. 2. Check for interruption of the power supply. 42 IBM System x3250 M2 Types 4190 and 4194: Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

Table
4.
Abbreviated
list
of
POST
error
codes
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
I9990305
An
operating
system
was
not
found.
1.
Make
sure
that
a
bootable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests.
3.
Reseat
the
following
components:
a.
Hard
disk
drive
b.
CD
or
DVD
drive
and
cables
c.
(Trained
service
technician
only)
System
board
4.
Replace
the
components
listed
in
step
3
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
I9990650
AC
power
has
been
restored.
1.
Check
the
power
cables.
2.
Check
for
interruption
of
the
power
supply.
42
IBM
System
x3250
M2
Types
4190
and
4194:
Installation
Guide