Icom D-STAR Instruction Manual - Page 34

Maintenance - manuals

Page 34 highlights

7 MAINTENANCE n Troubleshooting If your repeater seems to be malfunctioning, please check the following points before sending it to a service center. PROBLEM POSSIBLE CAUSE SOLUTION REF. Does not turn ON. • Power connector has a poor contact. • Blown fuse. • Check the connector pins and re-connect the p. 5 DC power cable. • Check for the cause, then replace the fuse. p. 31 N o t r a n s m i t o u t p u t • Antenna or coaxial cable has problems. power, or only few output power. • ­C heck, and if necessary, replace the coaxial pgs. cable or solder the antenna connector again. 3, 5 Sensitivity is low and • Antenna or coaxial cable has problems. only strong signals are operatable. • Check, and if necessary, replace the coaxial pgs. cable or solder the antenna connector again. 3, 5 Does not function even • The repeater controller, ID-RP2C, setting • Read the instruction manual of the ID-RP2 - a signal is received. is wrong. (supplied with the ID-RP2C) and correct the setting of the repeater controller, ID-RP2C. PC does not recognize • Too long USB cable is used. • Use a shorter USB cable. p. 6 the repeater The settings cannot be • Too long USB cable is used. programmed into the repeater properly. • Use a shorter USB cable. p. 30 n About cleaning DO NOT use chemical agents such as benzine or alcohol when cleaning, as they can damage the repeater's surfaces. n Fuse replacement If the fuse blows or the repeater stops functioning, find the source of the problem if possible, and replace the damaged fuse with a new, rated one as shown below. Fuse: FGB10A 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

7
31
MAINTENANCE
n
About cleaning
DO NOT use chemical agents such as benzine or
alcohol when cleaning, as they can damage the re-
peater’s surfaces.
n
Fuse replacement
If the fuse blows or the repeater stops functioning,
find the source of the problem if possible, and replace
the damaged fuse with a new, rated one as shown
below.
Fuse: FGB10A
n
Troubleshooting
If your repeater seems to be malfunctioning, please
check the following points before sending it to a ser-
vice center.
PROBLEM
Does not turn ON.
No transmit output
power, or only few
output power.
Sensitivity is low and
only strong signals are
operatable.
Does not function even
a signal is received.
PC does not recognize
the repeater
The settings cannot be
programmed into the
repeater properly.
POSSIBLE CAUSE
• Power connector has a poor contact.
• Blown fuse.
• Antenna or coaxial cable has problems.
• Antenna or coaxial cable has problems.
• The repeater controller, ID-RP2C, setting
is wrong.
• Too long USB cable is used.
• Too long USB cable is used.
SOLUTION
• Check the connector pins and re-connect the
DC power cable.
• Check for the cause, then replace the fuse.
Check, and if necessary, replace the coaxial
cable or solder the antenna connector again.
• Check, and if necessary, replace the coaxial
cable or solder the antenna connector again.
• Read the instruction manual of the ID-RP2
(supplied with the ID-RP2C) and correct the
setting of the repeater controller, ID-RP2C.
• Use a shorter USB cable.
• Use a shorter USB cable.
REF.
p. 5
p. 31
pgs.
3, 5
pgs.
3, 5
p. 6
p. 30