Priority A Channel, Call, Call

Page 12 highlights

2 PANEL DESCRIPTION Programmable function keys (Continued) The following functions can be assigned to the [Upper], [Lower] and [Emer] programmable function keys. SCAN Push to start and cancel scanning. • When the scan started with the Power ON Scan or Auto Scan function, push to pause the scan. The paused scan resumes after the specified time period has passed. PRIORITY A CHANNEL, PRIORITY B CHANNEL Push to select the Priority A or Priority B channel. PRIORITY A CHANNEL (REWRITE), PRIORITY B CHANNEL (REWRITE) ➥➥Push to select the Priority A or Priority B channel. ➥➥Hold down [Prio A (Rewrite)] or [Prio B (Rewrite)] for 1 second to assign the operating channel to the Priority A or Priority B channel, respectively. MEMORY CHANNELS 1, 2, 3, 4 Push to directly select memory channel 1, 2, 3 or 4, if programmed. LONE WORKER (p. 3-13) ➥➥Hold down for 1 second to turn ON the Lone Worker function. • When the Lone Worker function is turned ON, and no operation is performed for the specified time period, the Emergency function is automatically turned ON. ➥➥Push to turn OFF the Lone Worker function. MONITOR, MONITOR (AUDIBLE) ➥➥Push to turn the CTCSS (DTCS) or 2/5-tone squelch Mute ON or OFF. • Only during LMR operation, push to open any squelch functions, or deactivate any mute functions. • Only during PMR operation, push to activate one or two of the following functions on each channel. - Hold down to unmute the channel (Audible mode). - Push to mute the channel (Inaudible mode). - Push to send a 'reset code' after the communication is finished. NOTE: The unmute condition may automatically return to the mute condition, after a specified time period. ➥➥Depending on the presetting, holding down this key for 1 second cancels a scan. LOCK Hold down to electronically lock all programmable keys except [Moni(Audi)], [Call] (including Call A and Call B), [Emergency], [Surveillance] and [Lone Worker]. HIGH/LOW (p. 3-12) Select the transmit output power level temporarily or permanently, depending on the presetting. TALK AROUND ➥➥Hold down for 1 second to turn ON the Talk Around function. • The Talk Around function equalizes the transmit frequen- cy to the receive frequency for transceiver-to-transceiver communication. ➥➥Push to turn OFF the Talk Around function. DTMF AUTODIAL Push to transmit a programmed DTMF code. RE-DIAL Push to transmit the last-transmitted DTMF code. NOTE: TX memories are cleared after turning OFF the transceiver. WIDE/NARROW Push to select the IF bandwidth between Wide, Mid* or Narrow. *Depending on the presetting, the Mid channel width may not be selectable. CALL, CALL A, CALL B Push to transmit a 2/5-tone code. • Tone call transmission may be necessary before you call another station, depending on your signalling system. • [Call A] and/or [Call B] keys may be selectable when your system employs selective 'Individual/Group' calls. EMERGENCY Hold down for specified time period to transmit an emergency call. • The emergency call transmits with beeps, and the status indicator lights red. • The transceiver can transmit an emergency call without the beep sounding and the status indicator lighting. • If you want to cancel the emergency call, hold down the key again before transmitting the call. • The emergency call is transmitted one time only, or repeat- edly until receiving an acknowledgement signal, or until the power is turned OFF. When a matched 5-tone code signal is received, the emergency function can be cancelled, depending on the presetting. (PMR operation only) 2-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

2
PANEL DESCRIPTION
2-6
Programmable function keys (Continued)
The following functions can be assigned to the [Upper],
[Lower] and [Emer] programmable function keys.
SCAN
Push to start and cancel scanning.
When the scan started with the Power ON Scan or Auto
Scan function, push to pause the scan. The paused scan
resumes after the specified time period has passed.
PRIORITY A CHANNEL, PRIORITY B CHANNEL
Push to select the Priority A or Priority B channel.
PRIORITY A CHANNEL (REWRITE),
PRIORITY B CHANNEL (REWRITE)
Push to select the Priority A or Priority B channel.
Hold down [Prio A (Rewrite)] or [Prio B (Rewrite)]
for 1 second to assign the operating channel to the
Priority A or Priority B channel, respectively.
MEMORY CHANNELS 1, 2, 3, 4
Push to directly select memory channel 1, 2, 3 or 4, if
programmed.
LONE WORKER
(p. 3-13)
Hold down for 1 second to turn ON the Lone Worker
function.
• When the Lone Worker function is turned ON, and no
operation is performed for the specified time period, the
Emergency function is automatically turned ON.
Push to turn OFF the Lone Worker function.
MONITOR, MONITOR (AUDIBLE)
Push to turn the CTCSS (DTCS) or 2/5-tone squelch
Mute ON or OFF.
• Only during LMR operation, push to open any squelch
functions, or deactivate any mute functions.
• Only during PMR operation, push to activate one or two
of
the following functions on each channel.
- Hold down to unmute the channel (Audible mode).
- Push to mute the channel (Inaudible mode).
- Push to send a ‘reset code’ after the communication is
finished.
NOTE:
The unmute condition may automatically
return to the mute condition, after a specified time
period.
Depending on the presetting, holding down this key
for 1 second cancels a scan.
LOCK
Hold down to electronically lock all programmable keys
except [Moni(Audi)], [Call] (including Call A and Call B),
[Emergency],
[Surveillance] and [Lone Worker].
HIGH/LOW
(p. 3-12)
Select the transmit output power level temporarily or
permanently, depending on the presetting.
TALK AROUND
Hold down for 1 second to turn ON the Talk Around
function.
• The Talk Around function equalizes the transmit frequen
-
cy to the receive frequency for transceiver-to-transceiver
communication.
Push to turn OFF the Talk Around function.
DTMF AUTODIAL
Push to transmit a programmed DTMF code.
RE-DIAL
Push to transmit the last-transmitted DTMF code.
NOTE:
TX memories are cleared after turning OFF
the transceiver.
WIDE/NARROW
Push to select the IF bandwidth between Wide, Mid*
or Narrow.
*Depending on the presetting, the Mid channel width may not
be selectable.
CALL, CALL A, CALL B
Push to transmit a 2/5-tone code.
• Tone call transmission may be necessary before you call
another station, depending on your signalling system.
• [Call A] and/or [Call B] keys may be selectable when your
system employs selective ‘Individual/Group’ calls.
EMERGENCY
Hold down for specified time period to transmit an
emergency call.
• The emergency call transmits with beeps, and the status
indicator lights red.
• The transceiver can transmit an emergency call without the
beep sounding and the status indicator lighting.
• If you want to cancel the emergency call, hold down the key
again before transmitting the call.
• The emergency call is transmitted one time only, or repeat
-
edly until receiving an acknowledgement signal, or until the
power is turned OFF.
When a matched 5-tone code signal is received, the emer-
gency function can be cancelled, depending on the preset-
ting. (PMR operation only)