Icom IC-M85UL Instruction Manual - Page 15
Information, Connecting BC-226 together, WARNING: DO NOT, Status indicator, BC-226 Fuse replacement
View all Icom IC-M85UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
BATTERY CHARGING 4 Connecting BC-226 together DDInformation 1 You can connect up to 6 BC-226 together. 1. Remove the charger's right cover. (q) Status indicator 2 2. Snap the DC power plug to the other charger's DC power jack. (w) Light color Status 3 Orange Charging 4 Green Charging is completed. 5 Blinks orange and green Charging failed. It may have some problems. 6 WARNING: DO NOT connect more than 6 chargers together. It may result in an electric shock, cause a fire, overheating, or damage chargers. 7 BC-226 Fuse replacement If a fuse blows, find and repair the cause of the problem. 8 Then replace the damaged fuse with a new, adequately 9 rated fuse. Fuse type: 5 A/58 V (low profile mini blade fuse) 10 NOTE: Remove the fuse using the needle-nose pliers. 11 12 NOTE: 13 ••The transceiver MUST be turned OFF while charging. Otherwise: 14 - The battery will not be charged correctly. - The battery life may be shortened. 15 ••Do not transmit while charging. When you need to Fuse 16 transmit, remove the transceiver from the charger, and then turn ON the power. ••If the battery pack does not properly charge when it is attached to the transceiver, remove it from the transceiver and insert only the battery pack into the charger. 10