Icom IP501H Instruction Manual - Page 37

■ Setting item list continued, Headset XP, WS ProTac XP and WS Alert XP.

Page 37 highlights

4 SET MODE ■ Setting item list (continued) The shaded items (■■) are also displayed in the Basic Set mode. LItems or default values may differ according to a presetting. Ask your dealer for details. Item Description Option/range Default BT One Touch PTT Toggles receiving and transmitting by momentarily pushing [PTT] on a Bluetooth headset. Push [PTT] to talk, and push again to return to receive. LWhen "Enable" is selected, you do not have to hold down [PTT] while you are talking. LIcom has checked the PTT operation with some 3M Peltor headsets such as the WS Headset XP, WS ProTac XP and WS Alert XP. (Compatibility not guaranteed.) Enable or Disable Disable Show BT One Touch PTT Selects whether or not to display the BT One Touch PTT screen on the transceiver. When this item is set to "Enable," you can select whether or not to use the One Touch PTT function by pushing [FUNC]. This function enables you to push [PTT] on the Bluetooth microphone to transmit and push again to standby, so you can transmit without continuously holding down [PTT]. LIcom has checked the PTT operation with some 3M Peltor headsets such as the WS Headset XP, WS ProTac XP and WS Alert XP. (Compatibility not guaranteed.) Enable or Disable Disable BT PTT Beep Sounds a beep when the [PTT] switch on the Bluetooth headset is pushed. Enable or Disable Disable Search BT Device Searches for Bluetooth devices. Search ― Delete BT Device Deletes paired devices. ― ― Init BT Unit Initilizes the pairing list. NO or YES NO BT Unit Version Displays the version number of the internal Bluetooth unit. ― ― Recording Sets the Recording function. Enable or Disable Disable Record Call Type Sets the Call type to be recorded. Individual Call or All Individual Call Delete Recording Deletes the recorded audio. - - - or CLR --- Speakerphone Unit Select whether or not to use an optional speakerphone unit. Unuse or Use Use Show SIM Selection (For only IP503H) Selects whether or not to display the SIM switching item in the [FUNC] menu. LWhen "Enable" is selected, you can switch the SIM card by pushing [FUNC]. Enable or Disable Disable SIM Selection (For only IP503H) Selects the SIM card. ••Push to select "Select (SIM2)" (default), then push [Call history]. LAfter a while, the transceiver automatically restarts. ---(SIM1)* or Select (SIM2)* *If a name is assigned to each SIM slot, the name is displayed. - - - (SIM1) UTC Offset You can set this item when the transceiver uses the SNTP server for clock synchronization. Set the offset time between the UTC (Universal Time Coordinated) and local time. -14:00 ~ +14:00 (in 1 minute steps) 00:00 Daylight Saving Time You can set this item when the transceiver uses the SNTP server for clock synchronization. Select whether or not to use Daylight Saving Time (DST) for the clock. Enable or Disable Disable 4-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

4
SET MODE
4-7
■ Setting item list (continued)
The shaded items (
) are also displayed in the Basic Set mode.
L
Items or default values may differ according to a presetting. Ask your dealer for details.
Item
Description
Option/range
Default
BT One Touch PTT
Toggles receiving and transmitting by momen
-
tarily pushing [PTT] on a Bluetooth headset.
Push [PTT] to talk, and push again to return to
receive.
L
When “Enable” is selected, you do not have to
hold down [PTT] while you are talking.
L
Icom has checked the PTT operation with
some 3M Peltor headsets such as the WS
Headset XP, WS ProTac XP and WS Alert XP.
(Compatibility not guaranteed.)
Enable or Disable
Disable
Show BT One Touch
PTT
Selects whether or not to display the BT One
Touch PTT screen on the transceiver.
When this item is set to “Enable,” you can select
whether or not to use the One Touch PTT func
-
tion by pushing [FUNC].
This function enables you to push [PTT] on the
Bluetooth microphone to transmit and push again
to standby, so you can transmit without continu
-
ously holding down [PTT].
L
Icom has checked the PTT operation with
some 3M Peltor headsets such as the WS
Headset XP, WS ProTac XP and WS Alert XP.
(Compatibility not guaranteed.)
Enable or Disable
Disable
BT PTT Beep
Sounds a beep when the [PTT] switch on the
Bluetooth headset is pushed.
Enable or Disable
Disable
Search BT Device
Searches for Bluetooth devices.
Search
Delete BT Device
Deletes paired devices.
Init BT Unit
Initilizes the pairing list.
NO or YES
NO
BT Unit Version
Displays the version number of the internal
Bluetooth unit.
Recording
Sets the Recording function.
Enable or Disable
Disable
Record Call Type
Sets the Call type to be recorded.
Individual Call or All
Individual Call
Delete Recording
Deletes the recorded audio.
––– or CLR
–––
Speakerphone Unit
Select whether or not to use an optional speaker
-
phone unit.
Unuse or Use
Use
Show SIM Selection
(For only IP503H)
Selects whether or not to display the SIM switch
-
ing item in the [FUNC] menu.
L
When “Enable” is selected, you can switch the
SIM card by pushing [FUNC].
Enable or Disable
Disable
SIM Selection
(For only IP503H)
Selects the SIM card.
Push [▲]/[▼] to select “Select (SIM2)” (default),
then push [Call history].
L
After a while, the transceiver automatically restarts.
– – – (SIM1)* or Select (SIM2)*
*
If a name is assigned to each
SIM slot, the name is displayed.
–––(SIM1)
UTC Offset
You can set this item when the transceiver uses
the SNTP server for clock synchronization.
Set the offset time between the UTC (Universal
Time Coordinated) and local time.
–14:00 ~ +14:00
(in 1 minute steps)
00:00
Daylight Saving
Time
You can set this item when the transceiver uses
the SNTP server for clock synchronization.
Select whether or not to use Daylight Saving
Time (DST) for the clock.
Enable or Disable
Disable