Intel S5520HCT Product Specification - Page 76

Address Resolution Protocol ARP: The BMC sends and responds to ARPs supported

Page 76 highlights

Platform Management Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS • Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality. • Chassis intrusion detection (dependant on platform support) • Basic fan control using TControl version 2 SDRs • Fan redundancy monitoring and support • Power supply redundancy monitoring and support • Hot swap fan support • Acoustic management: Supports multiple fan profiles • Signal testing support: The BMC provides test commands for setting and getting platform signal states. • The BMC generates diagnostic beep codes for fault conditions. • System GUID storage and retrieval • Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on using a front panel button or a command. • Power state retention • Power fault analysis • Intel® Light-Guided Diagnostics • Power unit management: Support for power unit sensor. The BMC handles power-good dropout conditions. • DIMM temperature monitoring: New sensors and improved acoustic management using closed-loop fan control algorithm taking into account DIMM temperature readings. • Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs) • Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs) • Platform environment control interface (PECI) thermal management support • E-mail alerting • Embedded web server • Integrated KVM • Integrated Remote Media Redirection • Local Directory Access Protocol (LDAP) support • Intel® Intelligent Power Node Manger support 62 Revision 1.8 Intel order number E39529-013

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

Platform Management
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Revision 1.8
Intel order number E39529-013
62
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
Chassis intrusion detection (dependant on platform support)
Basic fan control using TControl version 2 SDRs
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot swap fan support
Acoustic management: Supports multiple fan profiles
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID LED.
It supports secure lockout of certain front panel functionality and monitors button presses.
The chassis ID LED is turned on using a front panel button or a command.
Power state retention
Power fault analysis
Intel
®
Light-Guided Diagnostics
Power unit management: Support for power unit sensor. The BMC handles power-good
dropout conditions.
DIMM temperature monitoring: New sensors and improved acoustic management using
closed-loop fan control algorithm taking into account DIMM temperature readings.
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported
on embedded NICs)
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on
embedded NICs)
Platform environment control interface (PECI) thermal management support
E-mail alerting
Embedded web server
Integrated KVM
Integrated Remote Media Redirection
Local Directory Access Protocol (LDAP) support
Intel
®
Intelligent Power Node Manger support