Intel SBX82 User Guide - Page 73

POST error messages

Page 73 highlights

POST error messages The following table provides an abbreviated list of the error messages that might appear during POST. See "Diagnostics" in the blade server Hardware Maintenance Manual and Troubleshooting Guide on the Intel Server Compute Blade SBX82 Resource CD for more information about the POST error messages. Table 6. Abbreviated list of POST error messages POST message Failing device or problem found 161 The real-time clock battery has failed. 162 A device configuration has changed. Suggested action Replace the battery. Make sure that your optional devices are turned on and installed correctly. 163 289 301 303 962 11xx 1162 1800 2400 2462 00019xxx ✏ NOTE If you are unable to start the Configuration/Setup Utility program, view the system event log in the management module. The time of day has not been set. Set the correct date and time. A failing DIMM was disabled. Make sure that the memory is correct for your blade server and that it is installed properly. Keyboard and keyboard controller • • Make sure that the keyboard/mouse/video select button LED on the front of the blade server is lit, indicating that the blade server is connected to the shared keyboard. Make sure that the keyboard cable is connected to the SBCE unit and nothing is resting on the keyboard keys. Parallel port configuration error Start the Configuration/Setup Utility program and make sure that the parallel-port setting is correct. Serial port error Make sure that the serial cable is connected correctly. Serial port configuration conflict Start the Configuration/Setup Utility program and make sure that the IRQ and I/O port assignments needed by the serial port are available. PCI adapter hardware interrupt Start the Configuration/Setup Utility program and make sure that the interrupt resource settings are correct. Video controller and memory • Make sure that the keyboard/mouse/video select button LED on the front of the blade server is lit, indicating that the blade server is connected to the shared monitor. • Make sure that the monitor is connected correctly to the SBCE unit. Processor x is not functioning or Make sure that processor x is installed correctly. If the failed the built-in test. problem remains, replace processor x. 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

59
POST error messages
The following table provides an abbreviated list of the error messages that might appear during
POST. See “Diagnostics” in the blade server
Hardware Maintenance Manual and Troubleshooting
Guide
on the
Intel Server Compute Blade SBX82 Resource CD
for more information about the
POST error messages.
Table 6. Abbreviated list of POST error messages
POST message
Failing device or problem found
Suggested action
161
The real-time clock battery has
failed.
Replace the battery.
162
A device configuration has
changed.
Make sure that your optional devices are turned on
and installed correctly.
NOTE
If you are unable to start the
Configuration/Setup Utility program, view the
system event log in the management module.
163
The time of day has not been set.
Set the correct date and time.
289
A failing DIMM was disabled.
Make sure that the memory is correct for your blade
server and that it is installed properly.
301
303
Keyboard and keyboard controller
Make sure that the keyboard/mouse/video select
button LED on the front of the blade server is lit,
indicating that the blade server is connected to
the shared keyboard.
Make sure that the keyboard cable is connected
to the SBCE unit and nothing is resting on the
keyboard keys.
962
Parallel port configuration error
Start the Configuration/Setup Utility program and
make sure that the parallel-port setting is correct.
11
xx
Serial port error
Make sure that the serial cable is connected correctly.
1162
Serial port configuration conflict
Start the Configuration/Setup Utility program and
make sure that the IRQ and I/O port assignments
needed by the serial port are available.
1800
PCI adapter hardware interrupt
Start the Configuration/Setup Utility program and
make sure that the interrupt resource settings are
correct.
2400
2462
Video controller and memory
Make sure that the keyboard/mouse/video select
button LED on the front of the blade server is lit,
indicating that the blade server is connected to
the shared monitor.
Make sure that the monitor is connected correctly
to the SBCE unit.
00019
xxx
Processor
x
is not functioning or
failed the built-in test.
Make sure that processor
x
is installed correctly. If the
problem remains, replace processor
x
.