Intel SC5650 Technical Product Specification - Page 152
Server Board S5500BC. - bios
View all Intel SC5650 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Appendix A: Integration and Usage Tips Intel® Server Chassis SC5650 TPS Appendix A: Integration and Usage Tips This appendix provides a list of useful information that is unique to the Intel® Server Chassis SC5650 and should be kept in mind while integrating and configuring your server. To maintain system thermals, fixed hard drive bays must be populated in the slots in this order: 1, 3, 5, 2, 4, 6. To maintain system thermals, hot-swap hard drive bays must be populated with either a hard drive or a drive blank. System fans are not hot swappable. If required, the CPU air duct(s) must be used to maintain system thermals. A CPU air duct is not required on the Intel® Server Board S5500BC. The chassis with Intel® Server Board S5500BC requires the use of shielded LAN cable to comply with Immunity regulatory requirements. Use of non shield cables may result in the product having insufficient immunity electromagnetic effects, which may cause improper operation of the product. Make sure the latest system software is loaded on the server. This includes system BIOS, FRU/SDR, BMC firmware, and hot-swap controller firmware. The latest system software can be downloaded from http://support.intel.com/support/motherboards/server. 138 Revision 1.2 Intel order number E39531-004