Intel SLWBR Product Specification - Page 13

Chassis Peripheral Bays

Page 13 highlights

Intel© LB440GX 2U Rack Server Chassis TPS Rev 1.0 5 Chassis Peripheral Bays 5.1 3.5" Floppy Drive Bay The chassis provides for the installation of a 3.5" floppy drive above the 5.25" CD-ROM drive bay. Removal of the top cover provides access for replacement of the floppy drive. 5.2 5.25" Drive Bay The chassis supports one half-height (1.6" high) removable media peripheral devices (typically CD- ROM). As a guideline based on cooling capabilities, the maximum recommended power per device is 17W. Thermal performance of specific devices must be verified to ensure compliance to the drive manufacturer's specifications. The 5.25" peripherals are removable from the front of the chassis after removal of the top cover. 5.3 LVD SCSI Hot-Swap Drive Bays The LB440GX 2U rack server chassis supports up to four (two 1" high and two 1.6" high) 3.5" LVD Ultra-2 SCSI hard drives which are accessible from the front of the chassis. Four low-cost SECC carriers are provided with the chassis to be installed on the hard drives. Thermal performance of specific hard drives must be verified to ensure compliance to the drive manufacturer's specifications. Peripherals must be specified to operate at a maximum ambient temperature of 50°C. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Intel
©
LB440GX 2U Rack Server Chassis TPS Rev 1.0
8
5 Chassis Peripheral Bays
5.1
3.5" Floppy Drive Bay
The chassis provides for the installation of a 3.5“ floppy drive above the 5.25” CD-ROM drive bay.
Removal of the top cover provides access for replacement of the floppy drive.
5.2
5.25" Drive Bay
The chassis supports one half-height (1.6” high) removable media peripheral devices (typically CD-
ROM).
As a guideline based on cooling capabilities, the maximum recommended power per device is
17W.
Thermal performance of specific devices must be verified to ensure compliance to the drive
manufacturer’s specifications.
The 5.25" peripherals are removable from the front of the chassis after removal of the top cover.
5.3
LVD SCSI Hot-Swap Drive Bays
The LB440GX 2U rack server chassis supports up to four (two 1” high and two 1.6” high) 3.5" LVD
Ultra-2 SCSI hard drives which are accessible from the front of the chassis. Four low-cost SECC
carriers are provided with the chassis to be installed on the hard drives.
Thermal performance of specific hard drives must be verified to ensure compliance to the drive
manufacturer’s specifications.
Peripherals must be specified to operate at a maximum ambient
temperature of 50
°
C.