Intel SLWBR Product Specification - Page 16

Hot-Swap Backplane Board Layout

Page 16 highlights

Intel© LB440GX 2U Rack Server Chassis TPS Rev 1.0 7.3 Hot-Swap Backplane Board Layout The backplanes reside in the hot-swap drive bay of the Intel® LB440GX 2U rack server chassis. Note this is a passive backplane, which means there is no firmware associated with it (no SAF-TE ASIC). As a result, server management will not be able to determine the status of each drive. The following diagram shows the layout of components and connectors on the hot-swap SCSI backplane printed circuit board. DISK POWER CONNECTOR 68Pin SCSI CON NECTOR SCSI ID SW SW2 SW1 DISK1 DISK0 OFF OFF 1 0 OFF ON 3 2 ON OFF 5 4 ON ON 9 8 TERMINATOR ENABLE : SHORT DIABLE : OPEN SE/LVD SCSI TERMINATOR Figure 6. Functional Diagram of the Hot-Swap SCSI Backplane 7.3.1 Configuration Options The following table lists all possible SCSI ID switch configurations of the Intel® LB440GX hot-swap SCSI backplane and the resulting SCSI ID for the position of each switch. SW SW ID of Disk ID of Disk 2 1 1 0 OFF OFF 1 0 OFF ON 3 2 ON OFF 5 4 ON ON 9 8 Table 7. HSBP Configuration Jumpers 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Intel
©
LB440GX 2U Rack Server Chassis TPS Rev 1.0
11
7.3
Hot-Swap Backplane Board Layout
The backplanes reside in the hot-swap drive bay of the Intel
LB440GX 2U rack server chassis.
Note
this is a passive backplane, which means there is no firmware associated with it (no SAF-TE ASIC).
As a result, server management will not be able to determine the status of each drive.
The following diagram shows the layout of components and connectors on the hot-swap SCSI
backplane printed circuit board.
68Pin SCSI CON
NECTOR
SCSI ID SW
SW2 SW1 DISK1 DISK0
OFF OFF
1
0
OFF
ON
3
2
ON
OFF
5
4
ON
ON
9
8
SE/LVD SCSI
TERMINATOR
TERMINATOR
ENABLE : SHORT
DIABLE
: OPEN
DISK POWER
CONNECTOR
Figure 6.
Functional Diagram of the Hot-Swap SCSI Backplane
7.3.1 Configuration Options
The following table lists all possible SCSI ID switch configurations of the Intel LB440GX hot-swap
SCSI backplane and the resulting SCSI ID for the position of each switch.
SW
2
SW
1
ID of Disk
1
ID of Disk
0
OFF
OFF
1
0
OFF
ON
3
2
ON
OFF
5
4
ON
ON
9
8
Table 7. HSBP Configuration Jumpers