Page 15 highlights

Intel© LB440GX 2U Rack Server Chassis TPS Rev 1.0 7 Hot-Swap SCSI Subsystem The Intel® LB440GX 2U rack server chassis has two independent, identical hot-swap backplanes. Each backplane supports two Ultra2 SCSI hot-swappable drives. Two configurable switches on the back of each backplane (see Figure 11) determine the identification of each drive. The backplanes are then daisy chained with a standard 68-pin Ultra-2 SCSI cable. The hot-swap SCSI subsystem supports the following features: § Hot-swapping of Ultra-2 SCSI drives, that allows connection of SCSI devices while the power is on. § Full dual mode LVD operation, compliant with Fast, Ultra and Ultra-2 SCSI bus operation. 7.1 Subsystem Purpose The Intel® LB440GX 2U rack server chassis hot-swap SCSI backplane performs the tasks associated with hot-swappable SCSI drives. The backplane design allows for: § Four high density 68 pin connectors for four LVD Ultra-2 compatible SCSI drives § Active termination on SCSI bus § Per-drive power control, including automatic slot power down upon drive removal 7.2 Abstract The Intel® LB440GX hot-swap SCSI backplane is made up of the following functional blocks: § SCSI Bus with Ultra-2 high density LVD 68 pin drive connectors, and active terminators § SCSI drive power control § Configuration jumpers 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Intel
©
LB440GX 2U Rack Server Chassis TPS Rev 1.0
10
7 Hot-Swap SCSI Subsystem
The Intel LB440GX 2U rack server chassis has two independent, identical hot-swap backplanes.
Each backplane supports two Ultra2 SCSI hot-swappable drives.
Two configurable switches on the
back of each backplane (see Figure 11) determine the identification of each drive.
The backplanes
are then daisy chained with a standard 68-pin Ultra-2 SCSI cable.
The hot-swap SCSI subsystem
supports the following features:
§
Hot-swapping of Ultra-2 SCSI drives, that allows connection of SCSI devices while the power
is on.
§
Full dual mode LVD operation, compliant with Fast, Ultra and Ultra-2 SCSI bus operation.
7.1
Subsystem Purpose
The Intel LB440GX 2U rack server chassis hot-swap SCSI backplane performs the tasks associated
with hot-swappable SCSI drives. The backplane design allows for:
§
Four high density 68 pin connectors for four LVD Ultra-2 compatible SCSI drives
§
Active termination on SCSI bus
§
Per-drive power control, including automatic slot power down upon drive removal
7.2
Abstract
The Intel
LB440GX hot-swap SCSI backplane is made up of the following functional blocks:
§
SCSI Bus with Ultra-2 high density LVD 68 pin drive connectors, and active terminators
§
SCSI drive power control
§