Intel SR1520ML User Guide - Page 87

After successful completion of the firmware update process, the firmware update

Page 87 highlights

iBMC Force Update 2 J3A1 3 Default Force Update AF002536 Figure 49. MiBMC Force Update Jumper in the Write Enable Position 4. Close the server system and reconnect AC power and power up the server. 5. Perform the standard iBMC firmware update procedure as documented in README.TXT file that is included in the given BMC Firmware Update package. 6. After successful completion of the firmware update process, the firmware update utility may generate an error stating that the iBMC is still in update mode. 7. Power down and remove AC power. 8. Open the server and move the jumper from the "enabled" position (pins 2-3) to the "disabled" position (pins 1-2). 9. Close the server system and reconnect AC power and power up the server. 10. Normal iBMC functionality is disabled when the force BMC update jumper is set to the "enabled" position. The server should never be run with the BMC force update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default, disabled position when the server is running normally. Intel® Server System SR1520ML User's Guide 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Intel
®
Server System SR1520ML User’s Guide
67
Figure 49. MiBMC Force Update Jumper in the Write Enable Position
4.
Close the server system and reconnect AC power and power up the server.
5.
Perform the standard iBMC firmware update procedure as documented in
README.TXT file that is included in the given BMC Firmware Update package.
6.
After successful completion of the firmware update process, the firmware update
utility may generate an error stating that the iBMC is still in update mode.
7.
Power down and remove AC power.
8.
Open the server and move the jumper from the “enabled” position (pins 2-3) to the
“disabled” position (pins 1-2).
9.
Close the server system and reconnect AC power and power up the server.
10.
Normal iBMC functionality is disabled when the force BMC update jumper is set to
the “enabled” position. The server should never be run with the BMC force update
jumper set in this position and should only be used when the standard firmware
update process fails. This jumper should remain in the default, disabled position
when the server is running normally.
AF002536
3
2
Default
Force
Update
J3A1
iBMC
Force
Update