Intel SR1530HCL Product Specification - Page 49

Appendix A: Integration and Usage Tips, System Management Software

Page 49 highlights

Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips This section provides a list of useful information that is unique to the Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCLS and should be kept in mind while integrating and server system. ƒ Only low-profile (1.2 inch or 30.48 mm) FBDIMMs can be used in the server systems. ƒ Processor fans are not needed and are not supported. The system fan blowers and power supply fans provide the necessary cooling needed for the system. Using a processor fan in these systems may cause Intel® System Management Software to incorrectly monitor the system fans. ƒ The air duct must be used to maintain system thermals. ƒ System fan blowers are not hot swappable ƒ A screw on the front edge of the top cover is required when the unit is installed in a useraccessible environment. ƒ The FRUSDR utility must be run to load the proper sensor data records for the server system onto the server board. ƒ Make sure the latest system software is loaded. This includes system BIOS, FRUSDR, and BMC firmware. The latest system software can be downloaded from http://support.intel.com/support/motherboards/server/S5000VCL/ Revision 2.2 41 Intel order number D71005-005

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS
Appendix A: Integration and Usage Tips
and SR1530CLR/SR1530HCLR/SR1530HCLSR
Revision 2.2
Intel order number D71005-005
41
Appendix A: Integration and Usage Tips
This section provides a list of useful information that is unique to the Intel
®
Server Systems
SR1530CL/SR1530HCL/SR1530HCLS and should be kept in mind while integrating and server
system.
±
Only low-profile (1.2 inch or 30.48 mm) FBDIMMs can be used in the server systems.
±
Processor fans are not needed and are not supported. The system fan blowers and
power supply fans provide the necessary cooling needed for the system. Using a
processor fan in these systems may cause Intel
®
System Management Software to
incorrectly monitor the system fans.
±
The air duct must be used to maintain system thermals.
±
System fan blowers are not hot swappable
±
A screw on the front edge of the top cover is required when the unit is installed in a user-
accessible environment.
±
The FRUSDR utility must be run to load the proper sensor data records for the server
system onto the server board.
±
Make sure the latest system software is loaded. This includes system BIOS, FRUSDR,
and BMC firmware. The latest system software can be downloaded from