Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips This section provides a list of useful information that is unique to the Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCLS and should be kept in mind while integrating and server system. Only low-profile (1.2 inch or 30.48 mm) FBDIMMs can be used in the server systems. Processor fans are not needed and are not supported. The system fan blowers and power supply fans provide the necessary cooling needed for the system. Using a processor fan in these systems may cause Intel® System Management Software to incorrectly monitor the system fans. The air duct must be used to maintain system thermals. System fan blowers are not hot swappable A screw on the front edge of the top cover is required when the unit is installed in a useraccessible environment. The FRUSDR utility must be run to load the proper sensor data records for the server system onto the server board. Make sure the latest system software is loaded. This includes system BIOS, FRUSDR, and BMC firmware. The latest system software can be downloaded from http://support.intel.com/support/motherboards/server/S5000VCL/ Revision 2.2 41 Intel order number D71005-005