Intel SR2500ALBRP User Guide - Page 113

Replacing a Fan Module

Page 113 highlights

8. Install the server system cover. For instructions, see "Installing the Server System Cover". 9. (Optional) Install the front bezel. For instructions, see "Installing the Front Bezel". 10. Plug all peripheral devices and the AC power cable(s) into the server. Replacing a Fan Module Replacing a Redundant Fan Module 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct". 5. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly". 6. Remove the optical drive cable if installed. 7. Remove the bridge board. For instructions, see Figure 61 "Removing the Bridge Board from the Server System" on page -71. 8. Remove the large air baffle. For instructions, see "Removing the Large Air Baffle". 9. Disconnect the fan cables from the mid-plane. Intel® Server System SR2500AL User's Guide 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

Intel® Server System SR2500AL User’s Guide
91
8.
Install the server system cover. For instructions, see
“Installing the Server System
Cover”
.
9.
(Optional) Install the front bezel. For instructions, see
“Installing the Front Bezel”
.
10.
Plug all peripheral devices and the AC power cable(s) into the server.
Replacing a Fan Module
Replacing a Redundant Fan Module
1.
Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information”
.
2.
Power down the server and unplug all peripheral devices and the AC power
cable(s).
3.
Remove the server system cover. For instructions, see
“Removing the System
Cover”
.
4.
Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct”
.
5.
Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly”
.
6.
Remove the optical drive cable if installed.
7.
Remove the bridge board. For instructions, see
Figure 61 “Removing the Bridge
Board from the Server System” on page -71
.
8.
Remove the large air baffle. For instructions, see
“Removing the Large Air Baffle”
.
9.