Intel SR2500ALBRP User Guide - Page 143

Table 10. Error Beep Codes Generated by Intel, Remote Management, Module

Page 143 highlights

In addition to the beep codes above, additional beep codes are provided if an Intel® Remote Management Module is installed. The Intel® Remote Management Module provides the following additional beep codes. Table 10. Error Beep Codes Generated by Intel® Remote Management Module Number of Beeps 1 1-5-1-1 1-5-2-1 1-5-2-3 1-5-2-4 1-5-4-2 1-5-4-3 1-5-4-4 Reason for Beeps and Action to Take Control panel CMOS clear has been initiated. Processor failure. Reseat or replace the failed processor. No processor is installed or the CPU 1 socket is empty. Reseat or replace the failed processor. Processor configuration error or CPU 1 socket is empty. Reseat or replace the failed processor. In a two-processor system, make sure the processors are identical. Front-side bus select configuration error. DC power unexpectedly lost. Chipset control failure. Power control failure. Intel® Server System SR2500AL User's Guide 121

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

Intel® Server System SR2500AL User’s Guide
121
In addition to the beep codes above, additional beep codes are provided if an Intel
®
Remote Management Module is installed. The Intel
®
Remote Management Module
provides the following additional beep codes.
Table 10. Error Beep Codes Generated by Intel
®
Remote Management
Module
Number of
Beeps
Reason for Beeps and Action to Take
1
Control panel CMOS clear has been initiated.
1-5-1-1
Processor failure. Reseat or replace the failed processor.
1-5-2-1
No processor is installed or the CPU 1 socket is empty. Reseat or replace
the failed processor.
1-5-2-3
Processor configuration error or CPU 1 socket is empty. Reseat or replace
the failed processor. In a two-processor system, make sure the processors
are identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2
DC power unexpectedly lost.
1-5-4-3
Chipset control failure.
1-5-4-4
Power control failure.