Intel SRCS16 Hardware User Guide - Page 22

Table 3-1 Intel® RAID Controller SRCS16 Connector and Jumper Description

Page 22 highlights

Table 3-1 defines the connectors on the RAID Controller SRCS16. Figure 3.1 provides the layout of the controller. The Write Pending connector (J4) provides a LED signal that indicates a write to disk has not been completed (dirty cache). Table 3-1 Intel® RAID Controller SRCS16 Connector and Jumper Description Jumpers and Connectors J1 J2 J3 J4 J5 J6 J7-J12 J13 J14 J15 J16, J17, JP1 Description 32-bit PCI (open - 64-bit PCI) BIOS enable; (installed - BIOS disabled) UART serial I/O connector for test (not present) Connector for Write Pending Indication LED Serial I/O connector for Serial EPROM I2C connector, used as the interface for the controller to communicate with a storage enclosure processor in an enclosure arrangement Port connectors (see Figure 3.1 for details) Mode 0 Select (closed - Mode 0) 3.3 V load sharing (open - disable) Battery backup daughter card connector (not used) Reserved for factory use Default Setting Open Open Open Open Open Open Open Open Open Open - Figure 3.2 RAID Controller SRCS16 Board Layout Reserved [J17] 3.3V Load Sharing [J14] 167 mm Speaker [U6] Reserved [J16] Memory Modules (5) Battery Connector (not used) [J15] Overview 56 mm Port 0 [J7] Port1 [J8] Port 2 [J9] Port 3 [J10] Port 4 [J11] Port 5 [J12] 32-bit PCI [J1] Write Pending Indication LED [J4] BIOS Enable [J2] Serial I/O Connector, Serial EEPROM [J5] UART Serial I/O [J3] Serial I2C Connector (Enclosure Management) [J6] Mode 0 (IOP Reset) [J13] 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Overview
22
Table 3-1 defines the connectors on the RAID Controller SRCS16. Figure 3.1 provides the
layout of the controller. The Write Pending connector (J4) provides a LED signal that
indicates a write to disk has not been completed (dirty cache).
Figure 3.2
RAID Controller SRCS16 Board Layout
Table 3-1
Intel® RAID Controller SRCS16 Connector and Jumper Description
Jumpers and
Connectors
Description
Default
Setting
J1
32-bit PCI (open - 64-bit PCI)
Open
J2
BIOS enable; (installed - BIOS disabled)
Open
J3
UART serial I/O connector for test (not present)
Open
J4
Connector for Write Pending Indication LED
Open
J5
Serial I/O connector for Serial EPROM
Open
J6
I
2
C connector, used as the interface for the controller to communicate
with a storage enclosure processor in an enclosure arrangement
Open
J7-J12
Port connectors (see Figure 3.1 for details)
Open
J13
Mode 0 Select (closed - Mode 0)
Open
J14
3.3 V load sharing (open - disable)
Open
J15
Battery backup daughter card connector (not used)
Open
J16, J17, JP1
Reserved for factory use
167 mm
56 mm
Port 0 [J7]
Port1 [J8]
Port 2 [J9]
Port 3 [J10]
Port 4 [J11]
Port 5 [J12]
32-bit PCI [J1]
BIOS Enable [J2]
UART Serial I/O [J3]
Write Pending Indication LED [J4]
Serial I/O Connector,
Serial EEPROM [J5]
Serial I2C Connector
(Enclosure Management) [J6]
Reserved
[J17]
3.3V Load
Sharing [J14]
Reserved
[J16]
Battery
Connector
(not used) [J15]
Mode 0 (IOP Reset) [J13]
Speaker
[U6]
Memory
Modules (5)