Intermec IF2 Basic Reader Interface Programmer's Reference Manual (BRI version - Page 91
FJCHGBLOCKLOCK, Purpose, Syntax, Examples
View all Intermec IF2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Chapter 4 - BRI Commands FJCHGBLOCKLOCK Purpose: Syntax: Examples: An extension to the WRITE command. WRITE FJCHGBLOCKLOCK implements the Fujitsu ChgBlockLock command. ChgBlockLock changes the BlockLock flags in a BlockGroup with a password. WRITE [flex_query_selector] FJCHGBLOCKLOCK(,,,) [TAGTYPE=] [WHERE ] = An integer from 0 to 31. = An integer from 0 to 65535. = An integer from 0 to 65535. = A 32-bit block group password. WRITE FJCHGBLOCKLOCK (0,0xffff,0xffff,0x11223344) H3035307B2831B380B0000C8F LCKOK OK> FJCHGWORDLOCK Purpose: Syntax: Examples: An extension to the WRITE command. WRITE FJCHGWORDLOCK implements the Fujitsu ChgWordLock command. This command changes one of two WordLock flags using the associated block group password. WRITE [flex_query_selector]FJCHGWORDLOCK (:, )= [, (:,)=]* [TAGTYPE=] [WHERE ] = Memory bank, must be 3, other values are reserved for future use. FJREADBLOCKLOCK Purpose: Syntax: Examples: An extension to the READ command. READ FJREADBLOCKLOCK implements the Fujitsu ReadBlockLock command. ReadBlockLock read the BlockLock flags in a BlockGroup. READ [flex_query_selector]FJREADBLOCKLOCK() [, FJREADBLOCKLOCK()] [TAGTYPE=] [WHERE ] = An integer from 0 to 31. READ FJREADBLOCKLOCK(0) H3035307B2831B380B0000C8F HOOOO H3035307B2831B380B0000C90 HFFOO OK> Basic Reader Interface Programmer Reference Manual 79